Electrical Connection; Icemaker; Remote Condensing Unit - Hoshizaki Serenity Series KMS-2000MLH Instruction Manual

Modular crescent cuber including condensing unit models srk-20h/3
Hide thumbs Also See for Serenity Series KMS-2000MLH:
Table of Contents

Advertisement

F. Electrical Connection

1. Icemaker

Power supply and ground connection are supplied from the remote condensing unit via
the wire harness provided. The wire harness is factory connected to the icemaker.
• Power supply and ground connection are supplied from the remote condensing
unit via the wire harness provided. Do not connect the wire harness leads to an
external power source.
• THE ICEMAKER MUST BE GROUNDED. Failure to properly ground the icemaker
could result in death, serious injury, or severe damage to equipment.
• To reduce the risk of electric shock, do not connect the remote condensing unit
power supply until after all wire harness connections have been made.
• Usually an electrical permit and services of a licensed electrician are required.
• The opening for the wire harness connection is 7/8" DIA to fit a 1/2" trade size conduit.
1) Route the wire harness from the icemaker to the remote condensing unit.

2. Remote Condensing Unit

• Electrical connection must be hard-wired to the remote condensing unit and must
meet national, state, and local electrical code requirements. Failure to meet these
code requirements could result in death, electric shock, serious injury, fire, or
severe damage to equipment.
• The remote condensing unit requires an independent power supply of proper
capacity. See the nameplate for electrical specifications. Failure to use an
independent power supply of proper capacity can result in a tripped breaker,
blown fuses, damage to existing wiring, or component failure. This could lead to
heat generation or fire.
• THE REMOTE CONDENSING UNIT MUST BE GROUNDED. Failure to properly
ground this remote condensing unit could result in death or serious injury.
• Electrical connections must be made in accordance with the instructions on the
"WARNING" tag provided with the pig tail leads in the remote condensing unit
junction box. See Figs. 15a and 15b.
• The remote condensing unit should have power for a minimum of 4 hours prior to
startup to prevent compressor damage.
• Usually an electrical permit and services of a licensed electrician are required.
• The maximum allowable voltage variation is ±10 percent of the nameplate rating.
• On single phase models, the white lead must be connected to the neutral conductor of the
power source. NOTICE! Miswiring results in severe damage to the icemaker.
WARNING
WARNING
24

Advertisement

Table of Contents
loading

This manual is also suitable for:

Serenity seriesKms-2000mlhSrk-20h/3