3. Bin Control
Before operating the icemaker, the bin control assembly must be installed correctly.
Failure to properly install the bin control assembly could result in ice backup and
unit damage.
1) Remove the 2 outer switch cover thumbscrews from the switch cover. See Fig. 10.
2) Remove the 2 inner switch cover thumbscrews. Slide the bin control out of the switch
mount.
3) Mount the bin control to the extension bracket (accessory bag) using the 2 thumbscrews
from the accessory bag. Route the bin control cable from the outer corner of the bin
control up through the gap in the extension bracket.
4) Using the 2 thumbscrews removed in step 2, mount the extension bracket to the switch
cover.
5) Replace the outer switch cover thumbscrews into the slots on the switch bracket. Do not
tighten.
Switch Bracket
Inner Switch Cover
Thumbscrews
Extension Bracket
Gap
Extension Bracket
(Accessory Bag)
Switch Mount
Bin Control
NOTICE
Outer Switch Cover
Thumbscrews
Switch Cover
Switch Bracket
Thumbscrews
Extension Bracket
Thumbscrews
(Accessory Bag)
Bin Control Cable
19
Extension Bracket
Gap