Setting Open and Close Modes
OPEN
1) If operator is in RUN mode, press CAL/RUN
2) Press SCROLL
key until display reads "OPEN MODE>MOM" or
SCROLL
"OPEN MODE>C-STP."Figure 11.
MOM=momentary contact, meaning you press and release the
key and the door will continue to move until it reaches
OPEN
OPEN
SE
its travel limit. (See NOTE)
C EA
C-STP=constant contact-stop, meaning if you release the key prior
to the door reaching its travel limit, the door will stop.
3) Press SET/CLEAR
SET
key to toggle between "OPEN MODE>C-STP" or
CLEAR
"OPEN MODE>MOM" on the display.
4) Press a SCROLL
key to shift to a new function and lock in the setting.
SCROLL
CAL
5) Press CAL/RUN
key to return to run mode.
RUN
CLOSE
1) If operator is in RUN mode, press CAL/RUN
SC L
2) Press SCROLL
key until display reads "CLOSE MODE>MOM,"
SCROLL
"CLOSE MODE>C-STP" or "CLOSE MODE>C-REV." Figure 12.
CLEA
EN
MOM=momentary contact, meaning you press and release the
CLOSE
key and the door will continue to move until it reaches
CLOSE
SE
its travel limit. (See NOTE)
L AR
C-STP=constant contact-stop, meaning if you release the key prior
to the door reaching its travel limit, the door will stop.
C-REV=constant contact-reverse, meaning if you release the key
prior to the door reaching its travel limit, the door will
reverse direction. (See NOTE)
SET
3) Press SET/CLEAR
key to toggle between "CLOSE MODE>C-STP" or
CLEAR
"CLOSE MODE>C-REV" or "CLOSE MODE>MOM" on the display.
4) Press a SCROLL
key to shift to a new function and lock in the setting.
SCROLL
5) Press CAL/RUN
CAL
key to return to run mode.
RUN
GCL-J&H
Standard Duty Operator
(Constant vs Momentary Contact)
CAL
key to enter calibration mode.
RUN
S O L
CLOSE
CAL
key to enter calibration mode.
LOSE
RUN
T
EN
ROLL
C L
LO E
www.geniecompany.com
NOTE: Momentary contact (MOM) or Constant Reverse (C-REV) may not be used
unless both the OPEN and CLOSE Limits have been set.
In situations where an external reversing device is either not installed or not
operating properly, Constant Contact (C-STP) MUST BE USED.
WARNING:
If momentary contact control is to be used, an external
reversing device such as a photocell system or sensing edge switch must be
used. See pages 5.7-5.8 for installation of entrapment protection devices.
NOTE: During adjustment of a Travel Limit, the Open and Close Modes will
automatically fail-safe to Constant Contact until the Limit has been set or reset.
At that time the Open and Close Modes will revert to their previous setting.
OPEN MODE MOM
CAL
RUN
Figure 11
CLOSE MODE C-STP