Commissioning; Burner Adjustments - Garland G24 SERIES Installation And Service Manual

G24 series gas-operated counter griddle
Table of Contents

Advertisement

COMMISSIONING

The whole of the gas installation, including the meter,
should be inspected, purged and tested for soundness in
accordance with the codes of the Country of destination .
1 . Ensure that all controls are in the " " position and turn
on the main gas supply .
2 . Remove the grease drawer & upper & lower fascia panels
and connect a U-gauge manometer to the pressure test
point on the main manifold . Operate the main burners in
accordance with the instructions given in the Operation
Instructions .
3 . Check that the supply pressure is correct . If necessary,
adjust the supply pressure to give the required setting .

Burner Adjustments

Fixing Screw
Required Length
of Opening
Page 10
Minimum Flame Setting
1 . Set gas tap to low " " position .
2 . Connect a U-gauage manometer to the pressure test
3 . With a screw driver, turn the adjuster on the tap body
When all the settings have been checked, remove the
U-gauge manometer, replace the pressure test point screw
and the front panels .
Injector Location
Aeration
Shutter
Tell the user of the location of the gas isolation cock for use in
an emergency .
Leave this Manual with the user or purchaser .
nipple located downstream of the gas tap .
clockwise to reduce or counter-clockwise to increase
pressure . Set pressure to correspond with Table E .
Test Point
Pilot
Adjuster
Low Flame
Adjuster
Part # 4521357 (12/07)