G. Install the Log Assembly
If the gas logs have been factory installed they
should not need to be positioned. If the logs have
been packaged separately, refer to the following
instructions.
STEP 1.
CAUTION: Logs are fragile! Carefully remove
the logs, grate and supporting cardboard from
the inside of the fi replace See Figure 14.5.
STEP 2.
Place the metal grate on top of the burner.
Position the legs of the grate into the forward
set of indentations in the burner top. The grate
should not cover any ports in the burner.
Figure 14.6 Front View
STEP 3. Log #1 (SRV2102-010):
over the brass orifi ce located behind the main burner. The log should be parallel to back refractory.
2 2
Figure 14.8 Front View
STEP 4. Log #2 (SRV2102-101):
over the left metal tab sticking up out of the top of log #1. The left end of this log sits on the burner surface.
54
1 1
Log #1 is the back burning log. The air shutter in the end of the burner tube goes
Place log #2 on top of log #1. The bottom side of this log has a slot in it that goes
Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. R • 6/09
Log Assembly: LOGS-6000GL
2 2
Figure 14.5
Figure 14.7 Top View
2 2
Figure 14.9 Top View
5 5
6 6
1
1
4 4
3 3
1 1
HUMP
HUMP
2102-910