Step 10 Finishing - Heat & Glo LifeStyle PIER-TVFL Installer's Manual

Table of Contents

Advertisement

Step 10
Finishing
Only non-
combustible
materials may be
used to cover the
black fireplace front.
CAUTION
26
The following diagram shows the minimum vertical
and corresponding maximum horizontal
dimensions of fireplace mantels or other
combustible projections above the top front edge
of the fireplace. See Figures 3 and 4 for other
fireplace clearances.
DRY WALL
12"
TOP FRONT
EDGE OF
FIREPLACE
Figure 13. Minimum Vertical and Maximum
Horizontal Dimensions of
Combustibles above Fireplace
WARNING
!
WHEN FINISHING THE FIREPLACE,
NEVER OBSTRUCT OR MODIFY THE
AIR INLET/OUTLET GRILLES IN ANY
MANNER.
IF JOINTS BETWEEN THE FINISHED WALLS AND
THE FIREPLACE SURROUND (TOP AND SIDES)
ARE SEALED, A 300° F. MINIMUM SEALANT MA-
TERIAL MUST BE USED. THESE JOINTS ARE
NOT REQUIRED TO BE SEALED. ONLY NON-
COMBUSTIBLE MATERIAL (USING 300° F. MINI-
MUM ADHESIVE, IF NEEDED) CAN BE APPLIED
AS FACING TO THE FIREPLACE SURROUND.
SEE THE FOLLOWING DIAGRAM
CEILING
31"
1 1/2"
MINIMUM