OPTIONAL REMOTE,
HI TEMP
WALL SWITCH
LIMIT SWITCH
OR THERMOSTAT
(ON CERTIFIED UNITS ONLY)
ON/OFF
FLAME SENSOR/SPARKER
IGNITION
MODULE
NEUTRAL
Figure 12. Direct Spark Ignition (DSI) Wiring Diagram
CAUTION
L2
(NEUTRAL)
100-254A
OPTIONAL
L1
JUNCTION
FAN
(HOT)
BOX
SWITCHES
120 VAC
BLACK
REM
FAN
GROUND
GROUND
TO
FIREPLACE
CHASSIS
WHITE
BLACK
HI-TEMP
ON/OFF SWITCH
LIMIT SWITCH
GAS
VALVE
REMOTE OUTLET
FAN OUTLET
GROUND
For Direct Spark Ignition (DSI) Wiring
Appliance Requirements
This appliance requires that 110-120 VAC be wired
to the factory installed junction box. Maintain correct
polarity when wiring the junction box.
Optional Accessories
Optional remote control kits require that 110-120
VAC be wired to the fireplace junction box.
Wall Switch
Position the wall switch in the desired position on a
wall. Run a maximum of 25 feet (7.8 m) or less of
16 A.W.G. minimum wire and connect it to the
fireplace ON/OFF switch pigtails.
LABEL ALL WIRES PRIOR TO
DISCONNECTION WHEN SERVICING
CONTROLS. WIRING ERRORS CAN CAUSE
IMPROPER AND DANGEROUS OPERATION.
VERIFY PROPER OPERATION AFTER
SERVICING.