Step 7 Gas Pressure Requirements; Step 8 Wiring The Fireplace - Heat & Glo 6000TRS-CE Installer's Manual

Hide thumbs Also See for 6000TRS-CE:
Table of Contents

Advertisement

Step 7
Gas Pressure
Requirements
Inlet Pressure
Manifold Pressure
Gas Rate
Max. Input(NETCV)
Burner Injector
Pilot Injector
Step 8
wiring the
Fireplace
Optional Accessories
Optional remote control
kits require that 230 VAC
be wired to the factory in-
stalled junction box before
the fireplace is permanently
installed.
wall Switch
Position the wall switch in the desired position on a wall. Run a maximum of 780
cm or less length of 0.102 cm diameter minimum wire and connect it to the fireplace
ON/OFF switch pigtails.
Pressure requirements for Heat & Glo gas
fireplaces are shown in the table below.
Natural Gas
Propane
(G20)
(G31)
20 mbar
30 or 50 mbar 30 or 50 mbar
4-8.7 mbar
15.7-25 mbar
m 3
m 3
.54
/
.24
/
h
10.0 kW
10.0 kW
DMS 33
1.8 mm
51
30
A tap is provided on the outlet side of the gas control for a
test gauge connection to measure the manifold pressure.
To measure inlet pressure, provisions must be made to
attach a test gauge to the tap immediately upstream of
the gas supply connection to the fireplace.
The fireplace and its individual shut-off valve must be
disconnected from the gas supply piping system during
any pressure testing of the system at test pressures in
excess of 60 mbar.
If the fireplace must be isolated from the gas supply
piping system by closing an individual shut-off valve, it
must be of the handle-less type.
NOTE: Electrical wiring must be installed by a
competent electrician.
For Standing Pilot Ignition wiring
Appliance Requirements
wARNING: DO NOT CONNECT 230 vAC
!
TO THE GAS CONTROL vALvE OR THE
APPLIANCE wILL MALFUNCTION AND THE
vALvE wILL BE DESTROYED.
Heat & Glo • 6000TRS-CE • 2049-900 Rev. R • 3/13
Butane
Natural Gas
(G30)
15.7-25 mbar
4-8.7 mbar
m 3
.16
/
h
h
9.5 kW
DMS 51
30
(G25)
25 mbar
.54
/
m3
h
8.5 kW
DMS 33
51
31