• The heat shield sections will overlap to match the wall
thickness (depth). The small leg in the shield rests on
top of the flue to properly space it from the pipe section
(see Figure 22).
Interior
Wall Shield
Outer Flue
Inner Flue
INTERIOR
Figure 22. venting through the wall
• The termination kit should pass through the wall fire-
stops from the exterior of the building.
• Adjust the termination cap to its final exterior position
on the building and interlock the flue sections.
wARNING: THE TERMINATION CAP MUST
!
BE POSITIONED SO THAT THE ARROw IS
POINTING UP.
• Use a high-temperature sealant gasket to seal between
the pipe and exterior firestop.
Heat & Glo • 6000TRS-CE • 2049-900 Rev. R • 3/13
Rear Vent
Heat Shield
3.8 cm min.
overlap
3.8 cm min.
Overlap
EXTERIOR
25