Installing Flue Components - Heat & Glo 6000TRS-CE Installer's Manual

Hide thumbs Also See for 6000TRS-CE:
Table of Contents

Advertisement

20
B. Installing Flue Components
After determining which set of starting collars will be used
(top or rear), follow venting instructions accordingly.
venting Out the Rear Flue
Remove the installed rear seal cap from the rear starting
collars by cutting the strap at each end (See Figure 15).
Follow the flue configuration tables accordingly.
Remove the 12.7 cm diameter heat shield from the 1.27 cm
diameter collar by sliding it out. Remove insulation piece.
!
venting Out the Top Flue
Remove the top flue collar seal cap by cutting the strap on
each end. Remove both pieces of insulation inside the top
two starting collars (see Figure 15).
Remove the 10.2 cm diameter heat shield from the 10.2
cm diameter collar by sliding it out.
You have to take the glass off again for positioning the
logs when the unit is finally installed in place and finished
around it. Reinstall the glass door. Attach flue system to
the top starting collars.
!
!
!
Insert screwdriver
here to remove cap.
Figure 15
Heat & Glo • 6000TRS-CE • 2049-900 Rev. R • 3/13
WARNING: THE TOP HEAT SHIELD (INSIDE
THE FIREBOx) MUST REMAIN ATTACHED IF
THE FLUE SYSTEM IS ATTACHED TO THE
REAR STARTING COLLARS. SEE FIGURE 15.
wARNING: THE REAR FLUE COLLAR SEAL
CAP MUST REMAIN ATTACHED TO THE REAR
FLUE COLLARS IF THE FLUE SYSTEM IS AT-
TACHED TO THE TOP STARTING COLLARS.
SEE FIGURE 15.
wARNING: FAILURE TO REMOvE INSULA-
TION IN THE SET OF COLLARS YOU ARE
USING COULD CAUSE A FIRE.
wARNING: YOU MUST LEAvE THE INSULA-
TION IN PLACE IN THE SET OF COLLARS YOU
ARE NOT USING.
Venting
or similar object
Out Rear
HEAT
SHIELD
DISCARD
INSULATION
CUT HERE
Venting
Out Top
SEAL
INSULATION,
SEAL
CAP
DISCARD
CAP
BOTH
PIECES
HEAT
SHIELD

Hide quick links: