Step 9 Finishing - Heat & Glo 6000TRS-CE Installer's Manual

Hide thumbs Also See for 6000TRS-CE:
Table of Contents

Advertisement

32
cauTiON
OPTIONAL WALL SWITCH
THERMOSTAT OR REMOTE
REMOTE SWITCH
PIGTAIL
Figure 29. Standing Pilot Ignition wiring Diagram
Step 9
Finishing
Only non-combustible
materials may be used
to cover the black
fireplace front.
Note: Factory installed non-combustible board may only be replaced with HHT
product code SUPERM-60 material and must be fully replaced in its entirety.
Heat & Glo • 6000TRS-CE • 2049-900 Rev. R • 3/13
wARNING: DO NOT CONNECT 230 vAC
!
TO THE wALL SwITCH OR THE CONTROL
vALvE wILL BE DESTROYED.
label all wires priOr TO DiscONNecTiON
wheN serviciNG cONTrOls. wiriNG errOrs
caN cause imprOper aND DaNGerOus Op-
eraTiON. verify prOper OperaTiON afTer
serviciNG.
TP/TH
TP
OFF
TH
ON
THERMOPILE
ON/OFF
SWITCH
The following diagram shows the minimum vertical and
corresponding maximum horizontal dimensions of fire-
place mantels or other combustible projections above the
top front edge of the fireplace. See Figures 2 , 3 and 4 for
other fireplace clearances.
NON-COMBUSTIBLE
BOARD
10,2
7,6
5,1
2,5
4
TOP FRONT EDGE
Note: all dimensions are shown in centimeters.
Figure 30. Minimum Vertical and Maximum Horizontal Dimensions
of Combustibles above Fireplace
wA R N I N G : w H E N F I N I S H I N G T H E
!
FIREPLACE, NEVER OBSTRUCT OR
MODIFY THE AIR INLET/OUTLET GRILLES
IN ANY MANNER.
THERMOCOUPLE
GAS VALVE
30,5
28
25,4
23
20,3
18
15,2
13
25,4
23
20,3
18
15,2
13
11,4
10,2
9
8
OF FIREPLACE