Advertisement

Models:
6000TRI-IPI
6000TRI-SP
WARNING: IF THE INFORMATION
IN THESE INSTRUCTIONS IS NOT
FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUS-
ING PROPERTY DAMAGE, PER-
SONAL INJURY, OR DEATH.
- Do not store or use gasoline or other flam-
mable vapors and liquids in the vicinity of this
or any other appliance.
- What to do if you smell gas
• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call
the fire department.
- Installation and service must be performed by a
qualified installer, service agency, or the gas
supplier.
Printed in U.S.A. Copyright 2005,
Heat & Glo, a brand of Hearth & Home Technologies Inc.
20802 Kensington Boulevard, Lakeville, MN 55044
This product is covered by one or more of the following patents: (United States) 4,112,913; 4,408,594; 4,422,426; 4,424,792; 4,520,791; 4,793,322;
4,852,548; 4,875,464; 5,000,162; 5,016,609; 5,076,254 5,191,877; 5,218,953; 5,328,356; 5,429,495; 5,452,708; 5,542,407; 5,613,487; (Australia)
543790; 586383; (Canada) 1,123,296; 1,297,746; 2,195,264; (Mexico) 97-0457; (New Zealand) 200265; or other U.S. and foreign patents pending.
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05
READ THIS MANUAL BEFORE INSTALLING OR
OPERATING THIS APPLIANCE. THIS INSTALLERS
GUIDE MUST BE LEFT WITH APPLIANCE FOR
FUTURE REFERENCE.
WARNING: IMPROPER INSTALLA-
TION, ADJUSTMENT, ALTERATION,
SERVICE OR MAINTENANCE CAN
CAUSE INJURY OR PROPERTY DAM-
AGE. REFER TO THIS MANUAL. FOR
ASSISTANCE OR ADDITIONAL INFOR-
MATION CONSULT A QUALIFIED IN-
STALLER, SERVICE AGENCY, OR THE
GAS SUPPLIER.
1. This appliance may be installed in an af-
termarket, permanently located, manufac-
tured (mobile) home, where not prohibited
by local codes.
2. This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with
other gases, unless a certified kit is used.
Please contact your Heat & Glo dealer with any
questions or concerns. For the number of your nearest
Heat & Glo dealer, please call 1-888-427-3973.
Installers Guide
Underwriters
Laboratories Listed
1

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo 6000TRI-IPI

  • Page 1 4,852,548; 4,875,464; 5,000,162; 5,016,609; 5,076,254 5,191,877; 5,218,953; 5,328,356; 5,429,495; 5,452,708; 5,542,407; 5,613,487; (Australia) 543790; 586383; (Canada) 1,123,296; 1,297,746; 2,195,264; (Mexico) 97-0457; (New Zealand) 200265; or other U.S. and foreign patents pending. Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05...
  • Page 2: Safety And Warning Information

    DO NOT place furniture or any other combustible Young children should be CAREFULLY SUPERVISED household objects within 36 inches of the fireplace when they are in the same room as the appliance. front. Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05...
  • Page 3: Table Of Contents

    Step 12 Before Lighting the Fireplace ........33 Step 13 Lighting the Fireplace ..........34 After the Installation ..............34 Section 4: Maintaining and Servicing Your Fireplace ..34 = Contains updated information. Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05...
  • Page 4: Section 1: Approvals And Codes

    Code (in Canada). These models may be installed in a bedroom or bed-sitting room in the U.S.A. and Canada. Heat & Glo Quality Systems registered by SGS ICS Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05...
  • Page 5: Section 2: Getting Started

    Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05...
  • Page 6 [1044mm] TOP STANDOFFS TOP VENT COLLARS REAR VENT COLLARS HOOD TRIM DOOR RATING PLATE AND LABELS LINE ELECTRICAL ACCESS ACCESS CONTROLS Figure 1. Diagram of the 6000TRI-IPI, 6000TRI-SP Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05...
  • Page 7: Section 3: Installing The Fireplace

    Sides ......... 1 ....25 (546 mm) into combustible construction. For minimum clearances, see the direct vent termination clearance diagrams on pages 24 and 25 in this manual. Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05...
  • Page 8: Step 2 Framing The Fireplace

    The center of the hole is one (1) inch (25.4mm) above the center of the horizontal vent pipe. 0” CLEARANCE TO Figure 3. Framing Dimensions 0” CLEARANCE FRAMING MEMBER Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05...
  • Page 9 1-1/4 TYP DVP48 8-9/16 1/2 TYP 12-9/16 NOTE: PIPES OVERLAP 1-1/4 INCHES AT EACH JOINT. Figure 4. DVP-Series Direct Vent Component Specifications (5-inch inner pipe / 8-inch outer pipe) Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05...
  • Page 10: Step 3 Installing The Vent System

    (For use on IPI units only) FIRESTOP DVP-TRAP DVP-TB1 DVP-TVHW SERIES (Required to have a minimum of 3 feet of vertical in the vent system) Figure 5. Vent System Components and Termination Kits Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05...
  • Page 11 2. Break the Flue Restrictor into two pieces. Do this by bending the part back and forth until it breaks (see Figure 8). Figure 6. Straight Up Vertical Venting BREAK HERE Figure 8. Flue Restrictor Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05...
  • Page 12 The use of two 90 elbows in a corner installation SETTINGS will affect space requirements (see Figure 2). Figure 11. Corner Installation Figure 10 Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05...
  • Page 13 NOTE: If a 90 elbow is first attached to the unit, the maximum horizontal run is 3-feet (914mm). Figure 13. Venting with One 90° Elbow Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05...
  • Page 14 15´ MAX. (4.65m) 4' MIN. (1.22m) 20´ MAX. (6.2m) V+H+H = 40' MAX.(12.4m) = 20´ MAX. (6.2m) +H = 40' MAX.(12.4m) Figure 15. Venting with Two 90° Elbows Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05...
  • Page 15 8´MAX. (2.48m) 20´MAX. (6.2m) V+H+H = 40 MAX. (12.4 m) H = 8´ MAX. (2.48 m) = 20´ MAX. (6.2 m) ´ Figure 16. Venting with three 90° elbows Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05...
  • Page 16 15' MAX. (4.65m) 4' MIN. (1.22m) 20' MAX. (6.2m) H +H = 20' MAX. (6.2m) +H +H = 40' MAX. (12.4m) NOTE: Figure 17. Venting with three 90° elbows Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05...
  • Page 17: Installing Vent Components

    HEAT INSULATION SHIELD DISCARD BOTH PIECES and HEAT SHIELD HEAT DISCARD SHIELD INSULATION HEAT SHIELD HERE Cut the seal cap strap and remove white gasket material. Figure 18 Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05...
  • Page 18 1/2 inch airspace between the shield and the combustible surface. See Figure 21. CORRECT INCORRECT COMBUSTIBLE SURFACE DIRECTION HEAT SHIELD 90 ELBOW Figure 21 Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05...
  • Page 19 Figure 23. 10" x 12" Hole and Vent Pipe HEAT SHIELD TRIM HEAT SHIELD IF TOO LONG, ADD TO SHIELD IF TOO SHORT EXTERIOR FIRESTOP INTERIOR FIRESTOP Figure 24. Heat Shield, Interior & Exterior Firestops Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05...
  • Page 20: Vent Termination

    NOTE: Keep insulation away from the vent pipe at least 1 inch (25mm). 7 1/4” NAILS (4 REQUIRED) (184mm) Figure 28. Trapezoid Termination Cap RAFTER CEILING CEILING FIRESTOP Figure 27. Attic Firestop Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05...
  • Page 21 Figure 29. Vent Termination Minimum Clearances CAUTION: IF EXTERIOR WALLS ARE FINISHED WITH VINYL SIDING, IT IS SUGGESTED THAT A VINYL PROTECTOR KIT BE INSTALLED. Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05...
  • Page 22: Step 4 Positioning, Leveling, And Securing The Fireplace

    • Secure the fireplace to the framing by nailing or screwing. the roof (for outside terminations). Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05...
  • Page 23: Step 5 Installing The Optional Heat-Zone Kit

    WARNING: 110-120 VAC MUST NEVER BE CONNECTED TO A CONTROL VALVE IN A MILLIVOLT SYSTEM. Figure 34. Gas Control System (Standing Pilot) Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05...
  • Page 24: Step 7 The Gas Supply Line

    (1/2) psig (3.5 kPa). Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05...
  • Page 25 BLACK S2 ON/OFF WHITE T2 SWITCH GAS VALVE RED T1 THERMOPILE BLACK S1 THERMOCOUPLE OPTIONAL WALL SWITCH, THERMOSTAT OR REMOTE Figure 37. Standing Pilot (SP) Ignition Wiring Diagram Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05...
  • Page 26: Step 9 Wiring The Fireplace

    REPLACED WITH TYPE 105 C RATED WIRE. BLOWER RECEPTACLE GROUND TEMPERATURE BLOWER SENSOR SWITCH 110-120 VAC SENSOR BLOWER SWITCH “FAN” RECEPTACLE SPEED CONTROL Figure 38. Fan Wiring Diagram Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05...
  • Page 27: Step 10 Finishing

    Note: There are 3 metal tabs holding the non-combustible board in place for shipping. These tabs are to be cut off or bent back before finishing around the fireplace front. Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05...
  • Page 28: Step 11 Installing Trim, Logs, And Ember Material

    • Pull the four glass latches out of the groove on the glass frame. Remove glass door from the unit (see Figure 42). ing, Inc. Reports 02-31919.01 and 02-31917.01.) Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05...
  • Page 29: Step 12 Before Lighting The Fireplace

    OFF position, in which AIR SHUTTER WING NUT case the air would have to be purged. Figure 44. Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05...
  • Page 30: Step 13 Lighting The Fireplace

    DO floating. See Figure 45. The flame sensor (IPI) or thermo- NOT use abrasive cleaners. pile/thermocouple tips should be covered with flame. See Figure 34. Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05...

This manual is also suitable for:

6000tri-sp

Table of Contents