Installation
instructions
EXHAUSTING THE DRYER (cont.)
CONNECTING
THE DRYER TO
HOUSE VENT
RIGID METAL TRANSITION DUCT
• For best drying performance, a rigid metal
transition duct is recommended.
• Rigid metal transition ducts reduce the risk of
crushing and kinking.
UL-LISTED FLEXIBLE METAL (SEMI-RIGID}
TRANSITION DUCT
• If rigid metal duct cannot be used, then UL-listed
flexible metal (semi-rigid)ducting
can be used
(Kit WXO8XlO077).
• Never install flexible metal duct in walls, ceilings,
floors or other enclosed spaces.
• Total length of flexible metal duct should not
exceed 8 feet (2.4 m).
• For many applications, installing elbows at both
the dryer and the wall is highly recommended
(see
illustrations at right). Elbows allow the dryer to sit
close to the wall without kinking and/or crushing
the transition duct, maximizing drying performance.
• Avoid resting the duct on sharp objects.
UL-LISTED FLEXIBLE METAL (FOIL-TYPE}
TRANSITION DUCT
In special installations, it may be necessaryto
connect the dryer to the house vent using a flexible
metal (foil-type)duct. A UL-listed flexible metal
(foil-type) duct may be used ONLYin installations
where rigid metal or flexible metal (semi-rigid)
ducting cannot be used ANDwhere a 4" diameter
can be maintained throughout the entire length
of the transition duct.
In Canada and the United States, only the flexible
metal (foil-type) ducts that comply with the "Outline
for Clothes Dryer Transition Duct Subject 2158A"
shall be used.
®
®
Never install flexible metal duct in walls, ceilings,
floors or other enclosed spaces.
Total length of flexible metal duct should not
exceed 8 feet (2.4 m).
Avoid resting the duct on sharp objects.
For best drying performance:
1. Slide one end of the duct over the clothes
dryer outlet pipe.
2. Secure the duct with a clamp.
3. With the dryer in its permanent position,
extend the duct to its full length. Allow 2 of
duct to overlap the exhaust pipe. Cut off and
remove excess duct. Keep the duct as straight
as possible for maximum airflow.
4. Secure the duct to the exhaust pipe with the
other clamp.
FOR TRANSITION
VENTING
(DRYER TO WALL}, DO:
,DO cut duct
as short as
possible and
install straight
into wall.
,,DO use elbows
when turns are
necessary.
bows
DO NOT:
'@
@
@
@
,DO NOT bend or
collapse ducting.
Use elbows if
turns are
necessary.
, DO NOT use
excessive
exhaust
length.
Cut duct as short
as possible.
, DO NOT crush
duct against
the wall.
, DO NOT set
dryer on duct.