Appendix A: Venting Terminations
Location
clearance to the termination frame above grade, veranda, porch, deck, or balcony
A
clearance to top of doors or operable windows
B
C
clearance to sides or bottom of door or operable windows
D
clearance to permanently closed window when installed with approved gas penetration termination
clearance to permanently closed window Recommended to prevent condensation
E
F
clearance to ventilated soffit located within a horizontal distance to 24 inches from centerline
of termination
clearance to unventilated soffit
G
H
clearance to outside corner
I
clearance to inside corner
J
clearance to each side of the vertical centerline of a metre or regulatory assembly to a maximum
vertical distance of 15ft
K
clearance to service regulator vent outlet
L
clearance to non mechanical air supply inlet to the building or combustion air inlet to other
appliance for appliance <= 100.000 BTU/H (30 KW)
clearance to forced air supply inlet
M
N
clearance above paved sidewalk or paved driveway located on public property
P
clearance under veranda, porch, deck, or balcony
Q
clearance above roof
clearance to adjacent walls and neighboring buildings
R
clearance from corner in recessed location
S
T
Maximum depth of recessed location
U
Maximum width for back wall of recessed location
V
Horizontal clearance between two terminations that are level
Horizontal clearance (centre to centre) between two terminations that are not level
W
Note 1: For N a vent shall not terminate directly above the sidewalk or paved driveway which is located between two single family dwellings and serve both dwelling.
Note 2: For P only permitted if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor
Note 3: For J, K, and as specified in CGA B149 installation code. Local codes or regulations may vary.
* Based on CGA B149.1 Natural Gas and Propane installation code. Local codes may vary, please check with local regulatory agency.
** Based on ANSI Z223.1/NFPA 54 National Fuel Gas Code. Local codes may vary, please check with local regulatory agency.
XG0211 - 040912.1

Appendix

30 inches to combustibles
16 inches to non-combustibles
22 inches to combustibles
16 inches to non-combustibles
H*38DF PRC Panorama Indoor Gas Fireplace
Canada*
12 inches
12 inches
9 inches
0
16 inches
22 inches
30 inches to combustibles
16 inches to non-combustibles
9 inches
12 inches
3 feet
3 feet
12 inches
6 feet
3 feet above air inlet
7 feet
22 inches to combustibles
16 inches to non-combustibles
2 feet
2 feet
12 inches
4 feet
2 feet
0
18 inches
USA**
12 inches
12 inches
12 inches
0
16 inches
22 inches
9 inches
12 inches
3 feet
3 feet
12 inches
7 feet
2 feet
18 inches
12 inches
4 feet
2 feet
0
18 inches
Page 31