IBM System x3650 M3 4255 Service Manual page 170

Problem determination and service guide
Hide thumbs Also See for System x3650 M3 4255:
Table of Contents

Advertisement

Table 10. Integrated management module error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 4, "Parts listing, Types 4255, 7945, and 7949 server," on page 157 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
The Chassis Event Log (CEL) on
system %1 is 75% full.
(%1 = CIM_ComputerSystem.
ElementName)
The Chassis Event Log (CEL) on
system %1 is 100% full.
(%1 = CIM_ComputerSystem.
ElementName)
%1 Platform Watchdog Timer
expired for %2.
(%1 = OS Watchdog or Loader
Watchdog;
%2 = OS Watchdog or Loader
Watchdog)
IMM Test Alert Generated by %1.
(%1 = user ID)
Security: Userid: '%1' had %2
login failures from an SSH client
at IP address %3.
(%1 = user ID;
%2 = MaximumSuccessive
LoginFailures (currently set to 5 in
the firmware);
%3 = IP address, xxx.xxx.xxx.xxx)
152
IBM System x3650 M3 Types 4255, 7945, and 7949: Problem Determination and Service Guide
Info
The IMM event log is 75% full.
When the log is full, older log
entries are replaced by newer
ones.
Info
The IMM event log is full. When
the log is full, older log entries
are replaced by newer ones.
Error
A Platform Watchdog Timer
Expired event has occurred.
Info
A user has generated a test alert
from the IMM.
Error
A user has exceeded the
maximum number of
unsuccessful login attempts from
SSH and has been prevented
from logging in for the lockout
period.
To avoid losing older log entries,
save the log as a text file and
clear the log.
To avoid losing older log entries,
save the log as a text file and
clear the log.
1. Reconfigure the watchdog
timer to a higher value.
2. Make sure that the IMM
Ethernet over USB interface
is enabled.
3. Reinstall the RNDIS or
cdc_ether device driver for
the operating system.
4. Disable the watchdog.
5. Check the integrity of the
installed operating system.
No action; information only.
1. Make sure that the correct
login ID and password are
being used.
2. Have the system
administrator reset the login
ID or password.