Table 6. Severity Scale
Scale
No repair action is recommended.
No immediate repair action is
required. Increase the frequency
of measurements and monitor the
condition of the machine.
Have a knowledgeable vibration
technician conduct more
advanced tests at the earliest
opportunity. Consider
maintenance action at the next
planned downtime or maintenance
period.
Have a knowledgeable vibration
technician conduct more
advanced tests as soon as
possible. Consider immediate
shutdown of the machine to make
repairs and prevent failure.
Action

ISO 10816 Standards

As an alternative to the Overall Vibration Severity Scale
included in the Meter, you can use the ISO Standard
10816-1 to evaluate the severity of overall vibration levels.
Table 7 is a chart that contains the values from this
standard. You can compare the overall vibration value
measured with the Meter to this table to identify the
vibration severity.
Table 7. Vibration Severity - ISO 10816-1
Machine
Class I
Small
in/s mm/s
Machines
0.01 0.28
0.02 0.45
0.03 0.71
0.04 1.12
0.07 1.80
0.11 2.80
0.18 4.50
0.28 7.10
0.44 11.20
0.70 18.00
1.10 28.00
1.77 45.9
Vibration Meter
Interpret Results
Class II
Class II
Class III
Medium
Large Rigid
Large Soft
Machines
Foundation
Foundation
GOOD
SATISFACTORY
UNSATISFACTORY
UNACCEPTABLE