G16X 3 Module - Extreme Networks e” series Hardware Installation Manual

Table of Contents

Advertisement

NOTE
If congestion is detected on a port with flow control enabled, a flow control PAUSE frame is sent out
that port. The PAUSE frame is not sent out on the other port in the group.
Table 55 describes the media types and the associated maximum distances for the GM-16X
Table 55: G16X
Mini-GBIC Type
1000BASE-SX
1000BASE-LX
1000BASE-ZX
1000BASE-BU
Mini-GBIC Ports
The G16X
3
module supports any of the following mini-GBICS:
• SX mini-GBIC
• LX mini-GBIC
• ZX mini-GBIC
• 1000BASE-BU mini-GBIC
NOTE
For more information about the supported mini-GBIC types, see "Mini-GBIC Types" on page 23.
LEDs
3
The G16X
module has the following LEDs:
• Module status
• Port status
• Diagnostics
For information about the LEDs and their activity on the G16X
page 293.
Software Requirements
The G16X
3
module requires ExtremeWare version 7.0.1b11 or later and BootROM 7.8 or later.
Hardware Requirements
Extreme Networks recommends using iPower power supplies (part numbers 50020, 50021, 50022) with
F96Ti modules in a BlackDiamond 6800 chassis. A BlackDiamond 6800 chassis with the original power
supplies (part number 50012) will power fewer G16X
supplies.
Extreme Networks Consolidated "e" and "i" Series Hardware Installation Guide
3
media types and distances
Media Type
Multimode fiber
Single-mode fiber
Single-mode fiber
Single-mode fiber
Maximum Distance
(meters)
550
10,000
70,000
10,000
3
module, see "I/O Module LEDs" on
3
modules than a chassis with iPower power
Configuring I/O Modules
3
module.
271

Advertisement

Table of Contents
loading

This manual is also suitable for:

I series

Table of Contents