Click OK. The switcher checks several possibilities, in the following order,
7.
and then responds accordingly.
Does the address include a specific file name, such as
a.
10.13.156.10/file_name.html? If so, the switcher downloads that HTML
page.
b.
Is there a file in the switcher's memory that is named "index.html"?
If so, the switcher loads "index.html" as the default startup page.
c.
If neither of the above conditions is true, the switcher loads the factory-
installed default startup page, "nortxe_index.html" (figure 6-2), also
known as the Control page.
Figure 6-2 — Control page

Control Page

The Control page (figure 6-2) provides a means to control the switcher and includes
links to three other pages: System Configuration, File Management, and I/O
Configuration. On the Control page, you can select an input to the preview output
and then cut or dissolve it to the program output or select an input to the program
ouput directly. The Control page also provides tools to check the frequency of an
input and to mute and freeze the outputs. Access the Control page by clicking the
Control tab.
ISS 408 Integration Seamless Switcher • Ethernet Operation