3.9
Battery Charger
The
generator
set
is
equipped
with
a
6-amp
float/equalize
battery charger to maintain the engine
starting
battery.
The
charger's
DC
leads
are
factory-wired.
Figure3-11
illustrates
the
battery
charger.
1
2
3_
5
zJ
1. LED indicators
2. Mounting flanges
3. Battery leads, 12 VDC
4. Fuse
5, AC powerco_
Figure 3-11 6-Amp Float/Equalize Battery Charger
Periodically
tighten
all
connections.
No
other
maintenance on the battery charger is required.
3.10 Storage Procedure
Perform
the
following
storage
procedure
before
removing
the generator
set from service for three
months or longer.
Follow the engine manufacturer's
recommendations
for storage, if available.
Note: Run
the
generator
set
monthly
whenever
possible.
3.10.1
Lubricating
System
1. Operate the generator set until it reaches operating
temperature, or about 15 minutes.
2. Stop the generator set.
3. While the engine is still warm, drain the engine
lubrication oil from the engine crankcase.
4. Refill the engine crankcase with oil. See Section
3.3.3 for oil recommendations.
5. Run the generator
set for a few minutes
to
distribute the clean oil.
6. Stop the generator set.
3.10.2
Fuel System
1. Start the generator set.
2. With the generator set running, shut off the gas
supply.
3. Run the generator set until the engine stops.
4. Place the generator
set master switch
in the
OFF/RESET position.
3.10.3
Cylinder
Lubrication
1.
2.
Remove the spark plugs.
Pour one tablespoon of engine oil into each spark
plug hole. Install the spark plugs and ground the
spark plug leads. Do not connect the leads to the
plugs.
3. Toggle the generator set master switch to crank the
engine two or three revolutions
to lubricate the
cylinders.
3.10.4
Exterior
Preparation
1. Clean the exterior surface of the generator set.
2. Seal all openings in the engine with nonabsorbent
adhesive tape.
3. Mask all areas to be used for electrical contact.
4. Spread a light film of oil over unpainted metallic
surfaces to prevent rust and corrosion.
TP-6195
1/04
Section 3 Scheduled
Maintenance
17