Setting The System Option Modes; Configuring The Fibre Channel Ports - HP XP20000/XP24000 Configuration Manual

Hp storageworks xp disk array configuration guide (t5278-96047, may 2011)
Hide thumbs Also See for XP20000/XP24000:
Table of Contents

Advertisement

Table 8 Host group modes (options) Windows
Host Group
Mode
6
13
40
CAUTION:
configured is disruptive and requires the server to be rebooted.

Setting the system option modes

The HP service representative sets the system option mode(s) based on the operating system and
software configuration of the host. Notify your HP representative if you install storage agnostic
software (such as backup or cluster software) that might require specific settings.

Configuring the Fibre Channel ports

Configure the disk array Fibre Channel ports by using P9000 or XP Command View Advanced
Edition Software or XP Remote Web Console (shown). Select the settings for each port based on
your SAN topology. Use switch zoning if you connect different types of hosts to the array through
the same switch.
34
Windows
Function
Parameter Setting Failure for TPRLO
When using the Emulex FCA in the Windows environment, the
parameter setting for TPRLO failed. After receiving TPRLO and
FCP_CMD, respectively. PRLO will respond when HostMode=0x0C/
0x2C and HostModeOption=0x06. (MAIN Ver.50-03- 1 4-00/00
and later)
SIM report at link failure.
Select HMO 13 when you want SIM notification when the number
of link failures detected between ports exceeds the threshold.
V-Vol expansion.
Select HMO 40 when all of the following conditions are satisfied:
The host mode 0C Windows or 2C Windows Extension is used.
You want to automate recognition of the DP-VOL capacity after
increasing the DP-VOL capacity.
Changing host group modes for ports where servers are already installed and
Default
Inactive
Inactive
Inactive

Advertisement

Table of Contents
loading

Table of Contents