HP XP20000/XP24000 Configuration Manual page 22

Hp storageworks xp disk array configuration guide (t5278-96047, may 2011)
Hide thumbs Also See for XP20000/XP24000:
Table of Contents

Advertisement

repeat the procedures in
and the device files and driver.
Example
# insf -e
insf: Installing special files for mux2 instance 0 address 8/0/0
:
:
#
Failure of the insf
If the device files for the new disk array devices cannot be created automatically, you must create
the device files manually using the mknodcommand as follows:
1.
Retrieve the device information you recorded earlier.
2.
Construct the device file name for each device, using the device information, and enter the
file names in your table. Use the following formula to construct the device file name:
cxtydz
where:
x = SCSI bus instance number
y = SCSI target ID
z = LUN
c stands for controller
t stands for target ID
d stands for device
The numbers x, y, and z are hexadecimal.
3.
Construct the minor number for each device, using the device information, and enter the file
names in your table. Use the following formula to construct the minor number:
0xxxyz00 where
xx = SCSI bus instance number, y = SCSI target ID, and z = LUN.
4.
Display the driver information for the system using the lsdev command.
Example
# lsdev
Character
:
188
#
5.
Enter the major numbers for the device drivers into the table. You should now have all required
device and driver information in the table.
22
HP-UX
"Verifying device recognition" (page 19)
:
:
e command indicates a SAN problem.
Block
Driver
Class
:
:
31
sdisk
disk
to verify new device recognition
:
:
:
:
:

Advertisement

Table of Contents
loading

Table of Contents