System Event Log - Dell PowerEdge R415 Owner's Manual

Server system
Hide thumbs Also See for PowerEdge R415:
Table of Contents

Advertisement

Table 1-3. System Messages
Message
Unsupported
memory
configuration.
DIMM mismatch
across slots
detected:
x,x,...
Warning: A fatal
error has caused
system reset!
Please check the

system event log!

Warning! Power
required exceeds
PSU wattage.
Check PSU and
system
configuration.
Warning!
Performance
degraded. CPU and
memory set to
minimum
frequencies to
meet PSU wattage.
System will
reboot.
(continued)
Causes
Invalid memory
configuration. Memory
modules are mismatched in
the specified slots.
A fatal system error occurred
and caused the system to
reboot.
The system configuration of
processor(s), memory
modules, and expansion
cards may not be supported
by the power supplies.
Corrective Actions
Ensure that the memory
modules are installed in a
valid configuration. See
"General Memory Module
Installation Guidelines" on
page 122.
Check the SEL for
information that was logged
during the error. See the
applicable troubleshooting
section in "Troubleshooting
System Memory" on
page 157 for any faulty
components specified in the
SEL.
If any system components
were just upgraded, return
the system to the previous
configuration. If the system
boots without this warning,
then the replaced
component(s) are not
supported with this power
supply. If low wattage power
supplies are installed, replace
them with High Output
power supplies to use the
components. See "Power
Supplies" on page 95.
About Your System
51

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents