Removing the Safety Cover

Warning: The safety cover protects you from exposure to an energy hazard in excess of
240 Volt-Amperes. Never operate the DFE module without the safety cover installed.
Advertencia: La cubierta de seguridad lo protege de exponerlo al riesgo de energía en
exceso de 240 Volt-Amperes. Nunca se debe opererar el modulo de DFE sin la cobertura
de seguridad instalada.
Warnhinweis: Die Sicherheitsabdeckung schützt vor Stromstössen von bis zu 240 VA.
Bitte nehmen Sie niemals die DFE Module ohne die Abdeckung in Betrieb.
Refer to Figure
1.
Attach the antistatic wrist strap (refer to the instructions on the antistatic wrist strap 
package).
2.
Place the DFE‐Gold module on an antistatic pad on a sturdy flat surface.
3.
Remove the seven screws fastening the safety cover to the seven standoffs on the main 
board. Save all screws for later use to reinstall the safety cover.
4.
If you are replacing the DRAM SIMM, proceed to "DRAM SIMM Replacement 
Procedure" on page
Replacement Procedure" on page B‐10. 
B‐3 and proceed as follows:
B‐7. If you need to replace the DIMM, proceed to "DIMM 
Matrix DFE-Gold Series PoE Module Hardware Installation Guide B-5
Gaining Access to Memory Modules