Examples, Slot Numbers/Module Placement In Matrix E7 Or N7 - Enterasys 6H308-48 Hardware Installation Manual

Dfe‐gold series module
Hide thumbs Also See for Enterasys 6H308-48:
Table of Contents

Advertisement

DFE Module Placement and Installation Rules
Figure 3-1
To ensure proper operation of the system, consider the following examples and rules for 
module placement in either chassis.
Example 1
Shows one module installed in the chassis. If the chassis is populated with only one 
4xxxxx, it must be installed in slot 1. 
Rule: If only one 4xxxxx is installed in the chassis, it must be in slot 1. Always install a 
4xxxxx in slot 1 of the chassis.
Example 2
Shows the chassis fully populated with 4xxxxx modules. By default, the chassis system 
can continue to operate after losing operation of all modules except the module in slot 1. 
(The loss of operation can be due to module reset, removal, or failure.) However, with the 
redundancy key installed, the system will remain operational provided that there is an 
operating module in slot 1 or 2.
3-4 Installation

Examples, Slot Numbers/Module Placement in Matrix E7 or N7

(Figure
3-1, A)
(Figure
3-1, B)
Caution: When installing a module into slot 1 of a non-operating chassis, it is strongly
recommended that the module have the desired version of firmware. Installation of a
replacement module into slot 1 of a non-operating chassis requires reconfiguration of the
system settings.
Precaución: Para instalar un módulo en la ranura 1 del chasis apagado, lo mejor es que
el módulo corresponda a la versión de firmware solicitada. Para instalar un módulo de
reemplazo en la ranura 1 del chasis apagado será necesario reconfigurar el sistema.