Preparing To Install The 4H4285-49 - Enterasys 6H308-48 Hardware Installation Manual

Dfe‐gold series module
Hide thumbs Also See for Enterasys 6H308-48:
Table of Contents

Advertisement

Preparing to Install the 4H4285-49

Preparing to Install the 4H4285-49
Follow the instructions below before installing a module in a Matrix E7, N3, N5, or N7 
chassis.
1.
Remove the blank panel covering the slot in which the module will be installed. All 
other slots must remain covered to ensure proper airflow for cooling. (Save the blank 
plate in the event you need to remove the module.)
2.
Remove the module from the shipping box. (Save the box and packing materials in 
the event the module needs to be reshipped.)
3.
Locate the antistatic wrist strap shipped with the chassis. Attach the antistatic wrist 
strap to your wrist and plug the cable from the antistatic wrist strap into the ESD 
grounding receptacle at the upper right corner of the chassis.
4.
Remove the module from the plastic bag. (Save the bag in the event the module must 
be reshipped.) Observe all precautions to prevent damage from Electrostatic 
Discharge (ESD).
5.
Examine the module for damage. If any damage exists, DO NOT install the module. 
Immediately contact Enterasys Networks. Refer to  "Getting Help" on page xviii.
6.
To install the module into a Matrix E7 or N7, proceed to "Installing 4H4285‐49 into a 
Matrix
proceed to "Installing 4H4285‐49 into Matrix N3 or N5 Chassis" on page 3‐10.
3-6 Installation
Caution: Failure to observe static safety precautions could cause damage to the
DFE-Gold module. Follow static safety handling rules and wear the antistatic wrist strap.
Do not cut the non-conductive bag to remove the module. Sharp objects contacting the
board or components can cause damage.
Precaución: Si no toma las medidas de seguridad necesarias para evitar descargas de
electricidad estática, es posible que el módulo se dañe. Siga los consejos de seguridad
para la manipulación del producto y no olvide utilizar la pulsera antiestática.
No corte la bolsa antiestática para sacar el módulo. Tenga en cuenta que si algún objeto
cortante entra en contacto con la placa o con los componentes, éstos podrían dañarse.
Warning: Install this module in a Matrix N3 or N7 chassis that has been installed in a
Restricted Access Location only. Access to the equipment by users must be restricted
through the use of a tool or lock and key or other means of security and is controlled by
the authority responsible for the location.
Advertencia: Instalar este modulo en un Matrix N3 o N7 que ha sido localizado en un
lugar de Acceso Restringido. Aceso al equipo debe ser restringido por el responsable del
sitio.
Warnhinweis: Installieren Sie dieses Modul nur in einem N3 oder N7 Chassis, wenn sich
diese in einer zugangsgeschützten Umgebung befinden. Der Bereich zu den
Komponenten sollte durch ein Schloß, einen Schlüssel oder sonstigen Sicherungen
geschützt und durch einen Verantwortlichen kontrolliert werden.
E7 or N7 Chassis" on page 3‐7. To install the module into an N3 chassis, 

Advertisement

Table of Contents
loading

Table of Contents