Enterasys 6H308-48 Hardware Installation Manual page 60

Dfe‐gold series module
Hide thumbs Also See for Enterasys 6H308-48:
Table of Contents

Advertisement

Using LANVIEW
Table 4-1 LANVIEW LEDs (continued)
LED
CPU
CPU (cont'd) Amber
4-4 Troubleshooting
Color
State
Off
Power off.
Amber
Blinking. Module in process
of booting.
Solid. Testing.
Green
Blinking. Image starts
running.
Solid. Functional.
Red
Solid. Processor in reset.
Green
Blinking. Indicates that the
and
module is in the process of
Amber
shutting down.
Alternately (67% on, 33%
and Off
off). Indicates that a
shutdown process has
completed. This indication
will remain for 60 seconds
before automatically
restarting.
Recommended Action
Ensure chassis has adequate power.
None.
If the LED remains amber for several
minutes, contact Enterasys Networks
for technical support.
None.
None.
None.
None. This state is activated when the
OFFLINE/RESET switch is pressed for
less than 1 second to start the process
of an orderly shutdown.
While in this state, do not remove any
DFE module.
While in this state, you have 60 seconds
to safely remove the DFE-Gold module
from the chassis.

Advertisement

Table of Contents
loading