Program Mode
All 3+1, 4+1 and 4+2 Expanded Formats Secondary Central Station Event Codes
If 0, 2, 3, 4, 5, 6, 7, 8 ,9, B or D is entered for address 50, the following data is automatically programmed for the
Secondary Central Station phone number event codes. Enter '0' for the Setting to disable the report to the Central
Station.

All 3+1, 4+1 and 4+2 Expanded Formats - Secondary

TABLE 3-6:
Address
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
1
Note: For Formats 'B' and 'D', this address is defaulted to '9' instead of 'F.'
46
Description
Secondary # Input Channel 1 Active Event Code
Secondary # Input Channel 2 Active Event Code
Secondary # Input Channel 3 Active Event Code
Secondary # Input Channel 4 Active Event Code
Secondary # Input Channel 1 Fault Event Code
Secondary # Input Channel 2 Fault Event Code
Secondary # Input Channel 3 Fault Event Code
Secondary # Input Channel 4 Fault Event Code
Secondary # AC Power Fault Event Code
Secondary # Earth Fault Event Code
Secondary # Low Battery Fault Event Code
Secondary # No Battery Fault Event Code
Secondary # Phone Line 1 Voltage Fault Event Code
Secondary # Phone Line 2 Voltage Fault Event Code
Secondary # NAC Fault Event Code
Secondary # Charger Fault Event Code
Secondary # Phone Number 1 Communication Fault Event Code
Secondary # Phone Number 2 Communication Fault Event Code
Secondary # System Off Normal Fault Code
Secondary # Input Channel 1 Active Restore Code
Secondary # Input Channel 2 Active Restore Code
Secondary # Input Channel 3 Active Restore Code
Secondary # Input Channel 4 Active Restore Code
Secondary # Input Channel 1 Fault Restore Code
Secondary # Input Channel 2 Fault Restore Code
Secondary # Input Channel 3 Fault Restore Code
Secondary # Input Channel 4 Fault Restore Code
Secondary # AC Voltage Fault Restore Code
Secondary # Earth Fault Restore Code
Secondary # Low Battery Fault Restore Code
Secondary # No Battery Fault Restore Code
Secondary # Phone Line 1 Voltage Fault Restore Code
Secondary # Phone Line 2 Voltage Fault Restore Code
Secondary # NAC Fault Restore Code
Secondary # Charger Fault Restore Code
Secondary # Phone Number 1 Communication Fault Restore Code
Secondary # Phone Number 2 Communication FAult Restore Code
Secondary # System Off Normal Restore Code
Secondary # System Test Message
Secondary # System Abnormal Test Message
Secondary # Upload/Download Request Code
Secondary # Upload Successful Code
Secondary # Download Successful Code
Secondary # Upload/Download Failed Code
411UDAC
Document #51073
Rev. D 12/09/2008
Setting
1
1
1
1
F
F
F
F
9
6
6
6
6
6
6
4
6
6
6
E
E
E
E
D
D
D
D
9
A
A
A
A
A
A
5
A
A
A
9
1
F
7
7
7
7
P/N 51073:D