6
4
8
2
10
5
40
2
3
4
Connecting the maintenance unit to the sewing machine head
–
Unscrew the cap 6.
–
Connect hose 3 (in accessory pack) with the distributor plate 7
located on the machine head.
–
Screw the cap 6 back on.
Setting the operating pressure
The operating pressure is 6 bar.
It can be read using the pressure gauge 4.
–
In order to set the pressure, pull up on the turning handle 2 and
turn.
In order to raise the pressure, turn the handle 2 clockwise. In order
to decrease the pressure, turn the handle 2 counter-clockwise.
6
7