12. Pneumatic Connections

CAUTION !
The pneumatic equipment will only function smoothly when the
system's supply pressure in between 8 and 10 bar.
The operating pressure of the sewing machine is 6 bar.
Pneumatic connection package
You can order a pneumatic connection package (order number
0797 003031) for stands with compressed-air maintenance units.
The package contains the following components:
Connection hose, 5 m long, (Ø =9 mm)
Hose connector gland and hose fitting
Coupling socket and coupling plug
Connecting the compressed-air maintenance unit
Fasten the compressed-air maintenance unit 1 to the stand brace
using the angle bracket, screws and strap.
Connect the maintenance unit to the compressed air supply using a
connection hose 5 (Ø =9 mm) and a R1/4" hose coupling.