11.5.6
Master reset
In order to ensure that the machine is properly positioned and that all
functions are correct, the following parameters must be verified or set
correctly:
·
Parameter F-111: set to 3000 rpm or less.
·
Parameter F-270: set to 6 (selection of positioning sensor)
·
Parameter F-272: calculate with the following formula:
Diameter of the motor belt pulley
Diameter of the machine belt pulley
A master reset will reset all parameter values to their default settings.
After a master reset, the machine-specific parameters must be
correctly specified again.
x 1000
GB
37