14
11
15
8
–
Fasten the Hall sensor 15 to the holder 8 using two screws 14
(M4 x 5).
–
Fasten the holder 8 with the Hall sensor 15 to the arm 8 using two
screws 10 (M4 x 8).
Guide the cable 11 through the clips 9.
–
Route cable 11 in the arm and then to the control cabinet under the
table plate.
–
Screw on the arm cover 7.
–
Connect the 9-pole Sub-D plug from the Hall sensor into "B18"
socket on the Efka DA321G controller (IPG / HSM / LSM).
12
2
–
Take out the section 12 from the protective belt cover 2.
Use a sharp knife to cut through the sections shown by 13.
–
Mount the protective belt cover on the machine head.
–
Mount the handwheel 1.
9
10
13
11
GB
25