Capacitance Measurement - UNI-T UT10A Operating Manual

Pocked-sized digital multimeter
Table of Contents

Advertisement

Model UT10A: OPERATING MANUAL
Measurement Operation(12)
F. Capacitance Measurement (see figure 3 with dotted line)
Warning
To avoid damage to the Meter or to the equipment under test, disconnect the
tested circuit power when measuring on line capacitors and discharge all high-
voltage capacitors before measuring capacitance.
Use the DC voltage function to confirm that the capacitor is discharged.
Never attempt to input over 60V in DC or 30V rms in AC to avoid personal
dangerous.
To measure capacitance, connect the Meter as follows:
1. Set the rotary switch to
2. Press SELECT button to select capacitance test.
3. Capacitance range open circuit has display value, please select relative
measuremnet mode by pressing RELATIVE button once.
4. Connect the test leads across with the object being measured.
The measured value shows on the display.
range.