  • Page 1: Table Of Contents

    Model UT2000: OPERATING MANUAL Table of Contents Title Page Introduction Attention International Electrical Symbols Features Environmental Conditions Technical Specification Dc Voltage Ac Voltage Dc Current AC Current Resistance Capacitance Temperature Frequency Diode 10 . Transistor hFE 11. Open circuit test 12.
  • Page 2: Introduction

    Model UT2000: OPERATING MANUAL £º INTRODUCTION UT2000 series are the large LCD DMM with accurate reading, stable quality, multifunctional and modern design of 3 1/2 and 4 1/2 handheld digital multimeter used for measuring DC voltage and current, AC voltage and current, resistance, capacitance, frequency, temperature, positive diode resistance, transistor hFE and short circuit testing.
  • Page 3: Features

    Model UT2000: OPERATING MANUAL FEATURES DC basic accuracy: (31/2) 0.5%; (4 1/2) 0.05%. Max. display:1999 (3 1/2 digit) ; 19999 (4 1/2 digit). Reading display frequency: 2-3 times per second. Automatic indication of polarity, decimal place and signs. Automatic indication of "1" for over-range."...
  • Page 4: Environmental Conditions

    Model UT2000: OPERATING MANUAL ENVIRONMENTAL CONDITIONS Guarantee accuracy: 23 ; relative humidity: <75%. Temperature range: working temperature: 0 to 104 storing temperature: -10 to 50 F to 122 Battery: 9Vbattery (NEDA1604,6F22 or similar type). Relative humidity: 0 ,<80%; 31 ,<50% Altitude: (operating) 2000 meters, and 10000 meters for storage.
  • Page 5: Technical Specification

    Model UT2000: OPERATING MANUAL TECHNICAL SPECIFICATION Accuracy: (a% reading + No. of digits), guaranteed for 1 year. 1. DC Voltage 3 1/2 Digit ACCURACY RANGE RESOLUTION 2001 2002/5 2006 2007 200mV 100 V (0.5%of rdg+1digit) 10mV 200V 100mV (0.8%of rdg+2digits)
  • Page 6: Ac Voltage

    Model UT2000: OPERATING MANUAL AC Voltage 3 1/2 Digit ACCURACY RANGE RESOLUTION 2001 2002/5 2006 2007 (1.2%of rdg+3digits) 200mV 100 V (0.8%of rdg+3digits) 10mV 200V 100mV (1.2%of rdg+3digits) 750V 4 1/2 Digit ACCURACY RANGE RESOLUTION 2003 2004 100 V (0.8%of rdg+10digits)
  • Page 7: Dc Current

    Model UT2000: OPERATING MANUAL 3. DC Current RANGE 3 1/2 Digit RESOLUTION ACCURACY 200 A 0.1 A (0.8%of rdg+1digit) 20mA 10 A 200mA 100 A (1.2%of rdg+1digit) 10mA (2%of rdg+5digits) 20 A 10n A RANGE 4 1/2 Digit RESOLUTION ACCURACY 0.1 A...
  • Page 8: Ac Current

    Model UT2000: OPERATING MANUAL AC Current RANGE 3 1/2 Digit RESOLUTION ACCURACY (1%of rdg+3digits) 20mA 10 A 200 A 0.1 A (1.8%of 200mA 100 A rdg+3digits) 10mA (3%of rdg+7digits) 20 A 10n A RANGE 4 1/2 Digit RESOLUTION ACCURACY 0.1 A (0.8%of...
  • Page 9: Resistance

    Model UT2000: OPERATING MANUAL 5. Resistance 3 1/2 Digit ACCURACY RANGE RESOLUTION 2001 2002/5 2006 2007 (0.8%of rdg+3digits) (0.8%of rdg+1digit) 200K (1%of rdg+2digits) [5%(of rdg-10digits)+10digits] 200M 100K 4 1/2 Digit ACCURACY RANGE RESOLUTION 2003 2004 (0.2%of (0.5%of 0.01 rdg+5digits) rdg+5digits) (0.2%of...
  • Page 10: Capacitance

    Model UT2000: OPERATING MANUAL which does not affect the accuracy of the reading. If the resistor under measurement is 100M , The reading will be 101.0, the actual value should be the display value minus 1.0: 101.0 - 1.0 = 100.0 M 6.
  • Page 11: Temperature

    Model UT2000: OPERATING MANUAL 7. Temperature ACCURACY RANGE RESOLUTION 2007 (0.75%of rdg+3digits) C~+400 (1.5%of rdg+15digits) C~1000 Temperature sensor: International standard K type (NiCr - NiSi) probe. 8. Frequency ACCURACY RANGE RESOLUTION 2006 2kHz (1.5%of rdg+5digits) 20kHz 10Hz ACCURACY RANGE RESOLUTION...
  • Page 12: Diode

    Model UT2000: OPERATING MANUAL 9. Diode MODEL RANGE DESCRIPTIONS TESTING CONDITION Display approx. Forward DC current approx. 1mA forward voltage series Reversed DC voltage of diode approx. 3V Overload protection: 250V DC or AC rms. 10 . Transistor hFE MODEL...
  • Page 13: Alarm

    Model UT2000: OPERATING MANUAL 13. Alarm ALARM SOUNDS Switch position Test leads position Mis- V, ,Hz, A or 10A BATT operation A,mA,2A Over Display >19999* range The testing value for range is meaningless. 14. Square wave output Frequency approx. 50Hz, range Vp-p 2V (only for UT2001).
  • Page 14 Model UT2000: OPERATING MANUAL 3. Input Current Jack: There is a 5x20mm fuse inside the “A” input jack. Over range measurement will burn the fuse and replacement should use the fuse of the same specification. “10A” input jack does not have fuse protection.
  • Page 15: Safety Rules

    Model UT2000: OPERATING MANUAL The choice of LCD display angle: see the following diagram. SAFETY RULES The Digit Multimeter is a precise electronic device. Do not tamper with the circuit and pay attention to the following: The Meter complies with IEC1010-1 pollution Degree2 CAT I 1000V, CAT II 600V over voltage standards.
  • Page 16 Model UT2000: OPERATING MANUAL Do not operate the Meter before the cabinet has been closed and screwed safely as terminal can carry voltage. Make sure before each measurement the Meter is set to the suitable range. Before using the Meter, please inspect the cabinet and test leads for damaged insulation or exposed metal.
  • Page 17 Model UT2000: OPERATING MANUAL 16. Do not operate the Meter under adverse environmental condition including high temperature and especially humid area as the Meter’s function may be ineffective after moisturizing. 17. To avoid damages and dangerous, do not change the circuit on your own.
  • Page 18: Maintenance

    Model UT2000: OPERATING MANUAL Maintenance(1) This section provides basic maintenance information including battery and fuse replacement instruction. Warning Do not attempt to repair or service your Meter unless you are qualified to do so and have the relevant calibration, performance test, and service information.
  • Page 19 Model UT2000: OPERATING MANUAL Maintenance(2) Remove the battery from the battery compartment. Replace the battery with a new 9V battery (NEDA 1604 or 6F22 or 006P). Rejoin the case bottom and battery and fuse compartment, and reinstall the screw. 3.Replacing the Fuses...
  • Page 20 Model UT2000: OPERATING MANUAL Copyright 2001 Uni-Trend International Limited. All rights reserved. Manufacturer: UNI-TREND TECHNOLOGY(DONG GUAN)LIMITED Address: Dong Fang Da Dao, Bei Shan Dong Fang Industrial Development District, Hu Men Town, Dong Guan City, Guang Dong Province, China Headquarters: Uni-Trend International Limited...