  • Page 1 P/N:110401111679X UT117C High-Precision True RMS Digital Multimeter User Manual...
  • Page 2 Preface Thank you for purchasing this brand new product. In order to use this product safely and correctly, please read this manual thoroughly, especially the safety notes. After reading this manual, it is recommended to keep the manual at an easily accessible place, preferably close to the device, for future reference.
  • Page 3: Table Of Contents

    Please read the instructions carefully and strictly follow all warning and Contents precautions. Warning: Before sue, please read the safety information carefully. UT117C is a handheld 60000-count multimeter with high reliability and safety. I. Overview ---------------------------------------------------------------------------- 4 It adopts high-resolution A/D converter and microcontroller data processing II. Features ----------------------------------------------------------------------------- 4 technology.
  • Page 4: Accessories

    UT117C User Manual UT117C User Manual Before measuring on-line resistance, diode or continuity, please switch off Optional magnetic hanging strap to enable performing measurement all powers of measured devices, and discharge all capacitors completely. without holding the multimeter by hand.
  • Page 5: External Structure

    UT117C User Manual UT117C User Manual ● Analog bar graph: 33 segments. Update for 32 times per second. VIII. Rotary Switch ● Range: Auto/Manual ● Polarity display: Auto ● Overrange indication: OL ● Low voltage indication: (About ≤3.6±0.2V) ● Operating temperature: 0℃~40℃ (32℉~104℉) ●...
  • Page 6: Button Descriptions

    UT117C User Manual UT117C User Manual IX. Button Descriptions 1) Short press this button to enter or exit data hold mode. In HOLD HOLD/ mode, they symbol “ ” is displayed on the LCD. Backlight 2) Long press to turn on/off the backlight. The backlight is turned off automatically in 5 minutes by default.
  • Page 7: Xi.operating Instructions

    UT117C User Manual UT117C User Manual XI. Operating Instructions 2. AC/DC voltage measurement (Figure 5) 1) Connect red test lead with V terminal, and black with COM. Please check the batteries (AAA 1.5V × 3) before use. If the battery power 2) Set the rotary switch to ACV or DCV position, select function (ACV or DCV) is low after the multimeter is powered on, the symbol “...
  • Page 8 UT117C User Manual UT117C User Manual Warning: 5. Resistance measurement (Figure 6) The input impedance of the multimeter is about 10MΩ. Measurement error 1) Set the rotary switch to “ ”, then short press SEL to switch to resistance will be produced when measuring circuit with high impedance. In most (Ω) measurement.
  • Page 9 UT117C (eliminate the error of current probe). Disconnect the test lead with measured circuit after all measurement 7. Capacitance measurement (Figure 8) operations are completed.
  • Page 10: Other Functions

    UT117C User Manual UT117C User Manual Please switch off the current of measured loop before connecting the Even the displayed result is that voltage is not present, it does not mean multimeter with the measured loop, otherwise it can present a risk of voltage is present.
  • Page 11: Technical Specifications

    UT117C User Manual UT117C User Manual XIII. Technical Specifications 3. AC voltage Accuracy: ± (a% of reading + b digits); guaranteed for one year Accuracy±(a% of Overload Ambient temperature: 23°C±5°C Range Resolution reading +b digit) protection Relative humidity: < 75% 600.00mV...
  • Page 12 UT117C User Manual UT117C User Manual 5. Frequency 7. AC current Accuracy±(a% of Overload Accuracy±(a% of Overload Range Resolution Range Resolution reading +b digit) protection reading +b digit) protection 99.99Hz 0.01Hz 6.0000A 0.0001A ±(1.5%+30) F 11A /1000V ACV: 600Vrms 999.9Hz 0.1Hz...
  • Page 13 1mV/1A, and the accuracy specified is the intrinsic * It is recommended to measure in REL mode if measured capacitance is accuracy of UT117C (eliminate the error of current probe). ≤100nF. * Least significant digit is allowed to be about 5 under short circuit.
  • Page 14: Use Of Magnetic Hanger (Ut-B23)

    After the APP is turned on, it enters navigation interface, searches “UT117C” automatically, and displays “UT117C” in the “To be connected” list, then select “UT117C” to connect. Or scan the QR code at the multimeter to connect. After successful connection, the Bluetooth symbol is displayed on the LCD always, the measurement results can be displayed through the communication between “iDMM2.0”...
  • Page 15: Maintenance And Repair

    UT117C User Manual UT117C User Manual 3. Application 2. Replace battery or fuse (Figure 11) Hang onto nail, hook or other objects, or attach to iron objects such as power Warning: distribution cabinet, photovoltaic combiner box, automobile engine hood, etc.