Remote start shutdown diagnostics

If the remote start activates but fails to stay running, the remote start module has the ability to inform you of
what may have caused the remote start failure. Before performing shutdown diagnostics it is important that
you let the remote start shut off on its own i.e. let it attempt to start 3 times then shut down, if this is not done
the unit will report the shutdown you used to shut off the remote start.
Note: Shutdown diagnostics does not report if the vehicles factory immobilizer is causing the problem.
To perform shutdown diagnostics:
1. With the ignition Off, press and hold the Control (valet switch) button.
2. Turn the ignition On and then back Off while holding the Control button.
3. Release the Control button.
4. Press and release the Control button. The LED on the control module flashes to report the last shutdown
for one minute or until the ignition is turned on, as shown in the following table:
LED Flashes
1 flash
2 flashes
3 flashes
4 flashes
5 flashes
6 flashes
7 flashes
8 flashes

Programming system features

The System Features Learn Routine dictates how the unit operates. It is possible to access and change most of
the feature settings using the Control module (Valet Switch) button.
1. Turn the ignition on, then off.
2. Select a Feature. Press and release the Control button the number of times corresponding to the
feature you wish to change. Then press and hold one more time to select the feature. The LED flashes
to indicate which feature # is selected.
3. Program the Feature. While holding the Control button, you can program the feature using the remote
control.
Pressing the button on the remote control selects the options in ascending order. The LED flashes indicatiing
which option is selected.
Once a feature is programmed:
Other features can be programmed within the same menu
The learn routine can be exited if programming is complete
To access another feature in the same menu:
Press and release the Control button the number of times necessary to advance from the feature you just pro-
grammed to the next one you want to program next, then press the Control button once more and hold it.
The learn routine exits if any of the following occurs:
The ignition is turned On
There is no activity for 30 seconds
The Control button is pressed too many times
© 2010 Directed Electronics. All rights reserved.
Shutdown Mode
Runtime expired
Over-rev shutdown
Low or no RPM, low battery (voltage and virtual tach modes)
Transmitter shutdown
(-) Hood shutdown (H3/4 GRAY)
Brake (+) Shutdown (H3/3 BROWN)
Neutral safety shutdown (H3/1BLACK/WHITE)
Wait-to-start timed out