Access level/Bay level:
OA administrator, OA operator
•
Restrictions:
The <asset tag> must be 1 to 32 characters long and includes all alphanumeric, underscore (_), and
dash (-) characters.
SET ENCLOSURE NAME
•
Command:
SET ENCLOSURE NAME "<enclosure name>"
•
Description:
Changes the enclosure name
o
The default enclosure name is the mid-plane serial number
o
•
Access level/Bay level:
OA administrator, OA operator
•
Restrictions:
The <enclosure name> must be 1 to 32 characters long and includes all alphanumeric, underscore
(_), and dash (-) characters.
SET ENCLOSURE PART_ NUMBER
•
Command:
SET ENCLOSURE PART_NUMBER "<part number>"
•
Description:
Sets the part number of the enclosure
•
Access level/Bay level:
OA administrator
•
Restrictions:
Must be 10 characters in length and the first character must be a digit. Acceptable characters are all
alphanumeric and the dash (-).
SET ENCLOSURE PDU_TYPE
•
Command:
SET ENCLOSURE PDU_TYPE {1|2|3|4}
•
Description:
Sets the enclosure PDU type to:
1=Single-phase
o
2=Three-phase
o
3=Three-phase, international
o
Enclosure management commands 104