You must have OA permission to perform this command.
ENABLE GUI_LOGIN_DETAIL
•
Command:
ENABLE GUI_LOGIN_DETAIL
•
Description:
Enables extended enclosure information available in the GUI on the login page
•
Access level/Bay level:
OA administrator, OA operator
•
Restriction:
None
ENABLE LLF
•
Command:
ENABLE LLF
•
Description:
Enables Link Loss Failover for Onboard Administrator Redundancy.
•
Access level/Bay level:
Operator, Administrator
•
Restrictions:
You must have OA permission to perform this command
RESTART OA
•
Command:
RESTART OA [<bay number>]
•
Description:
Resets the Onboard Administrator module specified by <bay number>. If no bay number is given,
then the Onboard Administrator the user is logged in to is restarted.
•
Access level/Bay level:
OA administrator, OA operator
•
Restrictions:
None
SET DATE
•
Command:
SET DATE MMDDhhmm [[CC]YY][TZ]
Enclosure management commands 102