BJC-3000
2. TROUBLESHOOTING BY SYMPTOMS
2.1 Troubleshooting by Symptoms
1. The Power Does
Not Turn On
<Measures>
Check the AC adapter
output voltage (+5V/24V)
Correct?
Yes
Replace the control
board
Replace the DC cable
<Symptom>· The printer does not turn on even when the POWER
button is pressed.
· The printer does not perform initialization even when
the POWER button is pressed.
<Cause>
Faulty AC adapter, control board, or DC cable.
+24V
+5V
GND
No
Replace the AC adapter
4-17
Part 4: Troubleshooting