Programming Procedures
Remote Access with Barrier Codes
Use this procedure to change the class of restriction for individual Remote
Access barrier codes. The class of restriction assigned to each barrier code
allows or denies the use of the following system features:
NOTE:
If barrier code requirements have not been established or have been
removed for Remote Access users, do not use this procedure; use "Remote
Access without Barrier Codes."
Restriction - determines whether Remote Access users can make local
and/or toll calls; the following settings are included:
— unrestricted
— t o l l r e s t r i c t e d
— outward restricted
ARS Facility Restriction Level (Hybrid/PBX only) – allows or restricts users
from using outgoing trunks by assigning a facility restriction level from 0
through 6. (The value assigned is the opposite from the FRL assigned to
the ARS route, where a value of 0 is the most, and a value of 6 is the
least restrictive.)
Allowed List Assignment- assigns Allowed Lists and is used when
Remote Access users are restricted from making local or toll calls.
Disallowed List Assignment - assigns Disallowed Lists and is used when
Remote Access users are not restricted from making local or toll calls.
A maximum of eight Allowed or Disallowed Lists can be assigned to each
barrier code. Class of restriction settings apply to individual barrier codes.
Entering Programming
Console: Select Menu
PC/SPM: Type SPM
Exiting Without Changes
To exit from any screen without making changes, select Exit on the console or
[F5]
press
on the PC before saving your entry or menu selection.
Sys Program
Exit
[F1]
press any key
Remote Access with Barrier Codes
[F5]
3-489