Install The Equipment Interface Module (Eim); Determine The Location - Aube Technologies EConnect Wireless Thermostat Kit TA7210 System Installation Manual

Wireless thermostat kit
Hide thumbs Also See for EConnect Wireless Thermostat Kit TA7210:
Table of Contents

Advertisement

Available languages

Available languages

Install the Equipment Interface Module (EIM)

Determine the location

The equipment interface module (EIM) consists of a relay and an antenna. They can be
installed either in the wiring compartment of the baseboard heater or in a 4-11/16" square
junction box.
Install EIMs at a minimum distance of 2 feet (0.6 m) of each other. This minimum
distance still applies even if the EIMs are on opposite sides of a wall.
Installing the EIM in a baseboard heater
You can install the EIM in the wiring
compartment of the baseboard heater if you
have any of the heaters listed in the following
table:
Manufacturer / brand
Cadet
Global Commander
King Electrical
Marley
Ouellet
Stelpro
TPI
The product has been tested for compatibility with the heaters listed above. If your
heater is not on the list, install the EIM on a 4-11/16" square junction box or replace
it with one listed.
Installing the EIM in a 4-11/16" square junction box
You can use a 4-11/16" square junction box in either of
the following conditions:
• You have a convector or fan-forced heater.
• You cannot install or do not wish to install the EIM in
the wiring compartment of the baseboard heater.
The junction box can be installed anywhere in the
house; for example, near the main electrical panel.
Series
F
CCB
K, CB, KP, M
2500, BKOC, QMKC
ODBA, ODI, ODIA, OFM, OPR
CBB, N, SCA, SCAS
2900C, 2900S, 3700, 3900
3
EConnect™ TA7210
Relay
Antenna
Antenna
Relay