Aube Technologies EConnect TA7210 Operating Manual

Aube Technologies EConnect TA7210 Operating Manual

Wireless programmable/non-programmable thermostat
Hide thumbs Also See for EConnect TA7210:
Table of Contents

Advertisement

Available languages

Available languages

Operating Manual

EConnect™ TA7210
Wireless Programmable/Non-programmable Thermostat
69-2473EF-01

Advertisement

Table of Contents
loading

Summary of Contents for Aube Technologies EConnect TA7210

  • Page 1: Operating Manual

    Operating Manual EConnect™ TA7210 Wireless Programmable/Non-programmable Thermostat 69-2473EF-01...
  • Page 2: Before You Begin

    Operating Manual Before you begin Do you know your thermostat configuration? To know whether your new thermostat is configured in programmable mode or non-programmable mode, look for the time and day display on the thermostat screen. If the time and day appear on the screen, the thermostat is configured as a programmable thermostat.
  • Page 3: Table Of Contents

    EConnect™ TA7210 Table of contents Non-programmable Programmable configuration configuration Basic operation Thermostat display in non-programmable mode ........4   Setting the temperature ...............5   Countdown mode (Décompte) ............6   Programmable mode Thermostat display in programmable mode ........8  ...
  • Page 4: Thermostat Display In Non-Programmable Mode

    Operating Manual Thermostat display in non-programmable mode If your thermostat is configured Heating Indicator in programmable mode, see more The number of flames depends on description on page 8. the heating intensity. The image disappears when heating stops. Indoor temperature Set temperature (room temperature) Lock...
  • Page 5: Setting The Temperature

    EConnect™ TA7210 Setting the temperature Set temperature Press to set the temperature. 69-2473EF—01...
  • Page 6: Countdown Mode (Décompte)

    Operating Manual Countdown mode Press Décompte (Countdown) to set a new temperature and to select the time you wish to hold this temperature setting. The thermostat will return to its previous or programmed temperature setting at the end of the countdown time. The countdown time is selectable from 15 minutes to 14 days.
  • Page 7 EConnect™ TA7210 Countdown mode (cont’d) The countdown time changes in real time to show the remaining time. Press Annuler any time to You can change the countdown cancel the Countdown mode. time and temperature any time. 69-2473EF—01...
  • Page 8: Programmable Mode

    Operating Manual Thermostat display in programmable mode The thermostat displays the current time and day when the thermostat is configured in programmable mode. When the thermostat is following the schedule, it also displays the current period of the schedule: Réveil (Wake), Départ (Leave), Retour (Return) or Sommeil (Sleep).
  • Page 9: Following The Heating Schedule

    EConnect™ TA7210 Following the heating schedule Exécute l’horaire (Run Schedule) appears on the screen when the thermostat is following the programmed schedule. Your thermostat has been programmed with an energy-saving schedule which can reduce your heating expenses by as much as 33%. Monday to Friday Saturday and Sunday (Lu, Ma, Me, Je &...
  • Page 10: Setting The Time And The Date

    Operating Manual Setting the time and the date 1 Press Menu. 2 Select Date & 3 Set the hour. 4 Set the minutes. heure. * Copy will appear only if the thermostat is linked to a remote control or an outdoor sensor. 69-2473EF—01...
  • Page 11 EConnect™ TA7210 Setting the time and the date (cont’d) 5 Set the year. 6 Set the month. 7 Set the day of 8 Enable/disable the month. Automatic Daylight Saving*. * When this function is enabled, the thermostat switches to daylight savings time on the second Sunday of March and to normal time on the first Sunday of November.
  • Page 12: Modifying The Heating Schedule

    Operating Manual Modifying the heating schedule 1 Press Menu. 2 Select Horaire. 3 Select the day or 4 Select the period the group* you you wish to modify. wish to modify. * The groups are: Lu-Ve (Monday-Friday), Sa-Di (Saturday-Sunday), and Lu-Di (Monday-Sunday). Selecting a group will apply the changes to all the days within that group.
  • Page 13 EConnect™ TA7210 Modifying the heating schedule (cont’d) 5 Set the time 6 Set the 7 Select another period 8 When all changes are (15-minute temperature. or press Sortir to go done, press Sortir intervals). to the day selection until you return to the menu (step 3).
  • Page 14: Temporary Hold (Maintien Temporaire)

    Operating Manual Temporary Hold (Maintien temporaire) Use Temporary Hold (Maintien temporaire) mode to temporarily bypass the schedule and set a new temperature. The thermostat will hold the new temperature during the current period. The thermostat will resume the heating schedule when the next period starts or if you press Annuler (Cancel).
  • Page 15: Permanent Hold (Maintien Permanent)

    EConnect™ TA7210 Permanent Hold (Maintien permanent) Use Permanent Hold (Maintien permanent) mode to bypass the schedule and set a new temperature for an indefinite period of time. To resume the heating schedule, press Annuler (Cancel). 1 Press until the 2 Press Permanent. 3 At any time, you can press desired temperature is Annuler to follow the...
  • Page 16: Copying The Heating Schedule

    Operating Manual Copying the heating schedule Use the Copie function to transmit the schedule settings of this thermostat to other EConnect™ wireless thermostats in your house. This function is available only if the thermostat is connected to a remote control or to an outdoor sensor.
  • Page 17 EConnect™ TA7210 Copying the heating schedule (cont’d) 4 Patientez flashes when 5 SUCC appears when 6 Press Sortir twice to return the schedule settings are the transmission is to the home screen. transmitted to the other completed. thermostats (this can last up to 2 minutes).
  • Page 18: Advanced Setup

    Operating Manual Advanced setup Setup functions Default setting Options Temperature and time formats * °C °C / °F 12h / 24h Programmable mode (Horaire) ** On (Oui) On/Off (Oui/Non) Adaptive Intelligent Recovery (Horaire On (Oui) On/Off (Oui/Non) Anticipé) *** You can set the temperature display unit in °C or °F. You can set the time display format in 12-hour or 24-hour (military time) if the thermostat is in programmable mode.
  • Page 19 EConnect™ TA7210 Accessing the advanced setup menu Press this button for 5 Advanced setup menu From the advanced setup seconds to access the menu, press advanced setup menu. select the setup functions and press OK. Adaptive Intelligent °C / °F 12h / 24h * Programmable mode Recovery *...
  • Page 20: Replacing The Batteries

    Operating Manual Replacing the batteries Thermostat Install 2 new alkaline AA batteries when the Piles faibles (Low batteries) warning starts flashing. It is recommended to replace batteries once a year, or when you will be away for more than a month. To access the batteries, pull the thermostat from its mounting plate.
  • Page 21: In Case Of Difficulty

    EConnect™ TA7210 In case of difficulty / Error codes Heating system does not • Check circuit breaker and reset if necessary respond “Signal Perdu” appears on the • The thermostat has lost communication with the screen wireless network (usually due to power outage). Otherwise, check circuit breaker and reset if necessary.
  • Page 22: Three-Year Limited Warranty

    Operating Manual Three-year limited warranty Honeywell warrants this product, excluding battery, to be free from defects in the workmanship or materials, under normal use and service, for a period of three (3) years from the date of purchase by the consumer. If at any time during the warranty period the product is determined to be defective or malfunctions, Honeywell shall repair or replace it (at Honeywell’s option).
  • Page 23: Regulatory Information

    EConnect™ TA7210 Regulatory information FCC Compliance Statement (Part 15.19) (USA only) to which the receiver is connected. This device complies with Part 15 of the FCC Rules. Operation is • Consult the dealer or an experienced radio/TV technician for help. subject to the following two conditions: EIM, thermostats and outdoor sensor 1) This device may not cause harmful interference, and...
  • Page 24 Automation and Control Solutions Honeywell International Inc. Honeywell Limited 1985 Douglas Drive North 705 Montrichard Golden Valley, MN 55422 Saint-Jean-sur-Richelieu, Quebec, J2X 5K8 http://yourhome.honeywell.com www.aubetech.com 69-2473EF-01 06-11 © 2011 Honeywell International Inc. ® U.S. Registered Trademark. All rights reserved. Printed in USA...
  • Page 25 Mode d’emploi EConnect TA7210 Thermostat programmable/non-programmable sans fil 69-2473EF-01...
  • Page 26 Mode d’emploi Avant de commencer Savez-vous la configuration de votre thermostat ? Pour savoir si votre nouveau thermostat est configuré en mode programmable ou en mode non programmable, vérifier si l’heure et le jour sont affichés à l’écran. S’ils apparaissent, cela signifie que le thermostat est configuré comme un thermostat programmable.
  • Page 27 EConnect TA7210 Table des matières Configuration Configuration non programmable programmable Utilisation de base Affichage en mode non-programmable ..........4   Réglage de la température ..............5   Mode Décompte ..................6   Mode programmable Affichage en mode programmable ............8  ...
  • Page 28: Affichage En Mode Non-Programmable

    Mode d’emploi Affichage en mode non-programmable Si votre thermostat est configuré en Indicateur de chauffage mode programmable, voir plus de Le nombre de flammes dépend de description à la page 8. l’intensité du chauffage. L’image disparaît lorsque le chauffage s’arrête. Température intérieure Température de consigne (température de la pièce)
  • Page 29: Réglage De La Température

    EConnect TA7210 Réglage de la température Température de consigne Appuyer sur pour régler la température. 69-2473EF—01...
  • Page 30: Mode Décompte

    Mode d’emploi Mode Décompte Appuyer sur Décompte pour régler une nouvelle température et de sélectionner la durée de maintien de la nouvelle température. Le thermostat retournera à son réglage de température précédent ou programmé à la fin du compte à rebours. La période de décompte est réglable de 15 minutes à...
  • Page 31 EConnect TA7210 Mode Décompte (suite) Le compte à rebours change en temps réel pour indiquer le temps restant. Appuyez sur Annuler en Vous pouvez modifier la période tout temps pour annuler le de décompte et la température mode Décompte. en tout temps. 69-2473EF—01...
  • Page 32: Affichage En Mode Programmable

    Mode d’emploi Affichage en mode programmable Le thermostat affiche l’heure et le jour lorsqu’il est configuré en mode programmable. Lorsque le thermostat suit l’horaire de chauffage, il affiche aussi la période en cours: Réveil, Départ, Retour ou Sommeil. La période n’est pas affichée lorsque vous placez le thermostat en Maintien temporaire ou en Maintien permanent.
  • Page 33: Utilisation De L'horaire De Chauffage

    EConnect TA7210 Utilisation de l’horaire de chauffage Le message Exécute l’horaire apparaît à l’écran lorsque le thermostat suit l’horaire programmé. Un horaire écoénergétique a été programmé dans votre thermostat, vous permettant ainsi de réduire votre facture d’électricité jusqu’à 33%. lundi à vendredi samedi et dimanche (Lu, Ma, Me, Je et Ve)) (Sa et Di)
  • Page 34: Réglage De L'heure Et Du Jour

    Mode d’emploi Réglage de l’heure et du jour 1 Appuyer sur 2 Sélectionner Date & 3 Régler l’heure. 4 Régler les Menu. Heure. minutes. * La fonction Copie n’apparaît que si le thermostat est relié à une télécommande ou une sonde extérieure. 69-2473EF—01...
  • Page 35 EConnect TA7210 Réglage de l’heure et du jour (suite) 5 Régler 6 Régler le mois. 7 Régler le jour 8 Activer/désactiver l’année. du mois. l’heure d’été automatique*. * Lorsque cette fonction est activée, le thermostat passe à l’heure d’été (avancée) le deuxième dimanche de mars et à...
  • Page 36: Modification De L'horaire De Chauffage

    Mode d’emploi Modification de l’horaire de chauffage 1 Appuyer sur 2 Sélectionner 3 Sélectionner le jour 4 Sélectionner la Menu. Horaire. ou le groupe* à période à modifier. modifier. * Les groupes sont: Lu-Ve, Sa-Di et Lu-Di. Lorsque vous sélectionnez un groupe, les changements seront apportés à...
  • Page 37 EConnect TA7210 Modification de l’horaire de chauffage (suite) 5 Régler l’heure 6 Régler la 7 Sélectionner une autre 8 Une fois tout (intervalles de température. période ou appuyer sur changement fait, 15 minutes). Sortir pour passer au appuyer sur Sortir menu de sélection du jusqu’à...
  • Page 38: Maintien Temporaire

    Mode d’emploi Maintien temporaire (Temporary Hold) Utiliser le mode Maintien temporaire pour déroger temporairement à l’horaire en réglant une nouvelle température. La nouvelle température sera maintenue pendant la période en cours. Le thermostat retournera à l’horaire de chauffage lorsque la période suivante débutera ou si vous appuyez sur Annuler.
  • Page 39: Maintien Permanent

    EConnect TA7210 Maintien permanente Utiliser le mode Maintien permanent pour déroger à l’horaire et régler une nouvelle température pendant une période indéfinie. Pour revenir à l’horaire de chauffage, appuyez sur Annuler. 1 Appuyer sur jusqu’à 2 Appuyer sur 3 En tout temps, vous pouvez ce que la température désirée Permanent.
  • Page 40: Copie De L'horaire De Chauffage

    Mode d’emploi Copie de l’horaire de chauffage Utiliser la fonction Copie pour transmettre l’horaire du thermostat aux autres thermostats sans fil EConnect de votre résidence. Cette fonction n’est disponible que si le thermostat est relié à une télécommande ou une sonde extérieure. Les réglages de l’horaire sont transmis à tout autre thermostat relié...
  • Page 41 EConnect TA7210 Copie de l’horaire de chauffage (suite) 4 Patientez clignote pendant 5 SUCC apparaît une 6 Appuyer deux fois sur que les réglages de l’horaire fois la transmission Sortir pour revenir à sont transmis aux autres complétée. l’écran d’accueil. thermostats (cela peut durer jusqu’à...
  • Page 42: Fonctions Avancés

    Mode d’emploi Fonctions avancés Fonctions de configuration Réglage par défaut Options Format de la température et de l’heure* °C °C / °F 12h / 24h Mode programmable (Horaire)*** Oui / Non Horaire Anticipé** Oui / Non Vous pouvez choisir d’afficher la température en ° C ou ° F. Vous pouvez choisir afficher l’heure en format 12 heures ou format 24 heures si le thermostat est en mode programmable.
  • Page 43 EConnect TA7210 Menu des fonctions avancés Appuyez sur ce bouton Menu des fonctions avancés Dans le menu des fonctions pendant 5 secondes avancés, appuyez sur pour accéder au menu pour sélectionner les fonctions des fonctions avancés. avancés et appuyez sur OK. °C / °F 12h / 24h * Horaire Anticipé...
  • Page 44: Remplacement Des Piles

    Mode d’emploi Remplacement des piles Thermostat Installer 2 piles alcalines AA neuves lorsque l’avertissement Piles faibles se met à clignoter à l’écran. Il est recommandé de remplacer les piles une fois par an, ou lorsque vous vous absentez pendant plus d’un mois. Pour accéder aux piles, tirer le thermostat de son socle.
  • Page 45: En Cas De Difficulté

    EConnect TA7210 En cas de difficulté / Codes d’erreur Le système de chauffage • Vérifier le disjoncteur et le réenclencher au besoin. ne répond pas “Signal Lost” apparaît à • Le thermostat a perdu la communication avec le réseau l’écran sans fil (habituellement après une panne de courant).
  • Page 46: Garantie Limitée De 3 Ans

    Mode d’emploi Garantie limitée de 3 ans Honeywell garantit ce produit, à l’exception des piles, contre tout vice de fabrication ou de matière dans la mesure où il en est fait une utilisation et un entretien convenables, et ce, pour trois (3) ans à partir de la date d’achat par le consommateur. En cas de défectuosité...
  • Page 47: Information Sur La Réglementation

    EConnect TA7210 Information sur la réglementation Déclaration de conformité à la FCC (partie 15,19) (États-Unis • Consulter un détaillant ou technicien radio-télé d’expérience pour seulement) obtenir de l’aide. Cet appareil est conforme à la Partie 15 des règles de la FCC. Le MIM, thermostat et sonde extérieure fonctionnement de ce système est assorti aux deux conditions Pour être conformes aux limites d’exposition aux radiofréquences...
  • Page 48 Automation and Control Solutions Honeywell International Inc. Honeywell Limited 1985 Douglas Drive North 705 Montrichard Golden Valley, MN 55422 Saint-Jean-sur-Richelieu, Quebec, J2X 5K8 http://yourhome.honeywell.com www.aubetech.com 69-2473EF-01 06-11 © 2011 Honeywell International Inc. ® Marque de commerce déposée aux É.-U. Tous droits réservés. Imprimé...

Table of Contents