Installation in a 4-11/16'' square junction box

ELECTRICAL HAZARD
Can cause electrical shock or equipment damage. Disconnect AC power before
beginning installation.
Wiring must comply with local electrical codes. Use special CO/ALR solderless connectors if
supply wires are made of aluminum.
1)
Mount the junction box on the wall. Punch out
knockout(s), install strain relief bushing(s) and feed
the supply wires and the heater wires. Punch out
another knockout to install the antenna (step 2).
3)
Clean the interior side of the junction box where the
relay will be installed. Peel off the adhesive backing
of the relay module and stick the relay inside the
junction box.
5)
Insert the antenna plug in the relay receptacle until
you hear a click.
Relay wires must be at the top
2)
Remove the locknut from the antenna and peel off
the adhesive backing. Feed the antenna cable
through the knockout opening and mount the
antenna. Put the locknut and tighten.
N L : For 120V application
L2 L1 : For 240V application
4)
Connect the supply wires and heater wires to the
relay.
See page 6 if you are connecting more than one
heater.
6)
Install a cover plate on the junction box and
apply power to the heater. Do not put the antenna
cover back yet.
ELECTRICAL HAZARD
Can cause electrical shock. Install junction box
cover plate before applying power.
5