Advertisement

Hardware Installations and Upgrades
Installing an Additional Hot Swap Power Supply Module
(BRP configuration only)
Note: This install procedure only applies to a chassis with redundant power supply capability.
DO NOT perform this install procedure if your chassis has a fixed power supply
Warning: Hazardous conditions, power supply: Hazardous voltage, current, and energy levels are
present inside the power supply. There are no user-serviceable parts inside it; servicing of
the power supply should be done only by technically qualified personnel.
Note: For Intel® Server Board S3000AH with SC5299BRP configuration only: Although a
redundant power supply may be added to the SC5299BRP chassis, the Intel® Server
Board S3000AH does not have a power supply failure detection mechanism in place to
support it. The P12 cable will be left unconnected.
1. Observe the safety and ESD precautions listed in
2. Insert finger into hole in middle of filler panel and remove filler panel from chassis.
.
3. Insert new hot swap power supply module until it clicks into place.

Figure 65. Inserting Additional Hot Swap Power Supply Module

52
UP

Figure 64. Removing Power Supply Filler Panel

Intel® Entry Server Chassis SC5299-E UP/DP/WS/BRP User Guide
Appendix A, "Safety
Information".
TP00916