Rebooting The Storage System; Disk Enclosure Not Found As Shown In Details Tab - HP StorageWorks P4000 User Manual

San solution
Hide thumbs Also See for StorageWorks P4000:
Table of Contents

Advertisement

2.
Server blades enclosure or system controller.
Allow up to 6 minutes for the system controller to come up completely and be discovered by the
CMC. If you cannot discover the storage system using the CMC after 6 minutes, contact Customer
Support.
3.
If you do not power on the disk enclosure first, the Storage System Details tab shows the status
with No Formatted Devices Available.
Figure 6 Disk enclosure not found as shown in Details tab
.
When powering off the storage system, be sure to power off the components in the following order:
1.
Power off the server blades enclosure or system controller from the CMC as described in
off the storage
2.
Manually power off the disk enclosure.
When you reboot the storage system, use the CMC, as described in
system" on page 44. This process reboots only the server blades enclosure or the system controller.

Rebooting the storage system

1.
Select a storage system in the navigation window and log in.
2.
Click Storage System Tasks on the Details tab and select Power Off or Reboot.
3.
In the minutes field, type the number of minutes before the reboot should begin.
Enter any whole number greater than or equal to 0. If you enter 0, the storage system reboots
shortly after you complete
NOTE:
If you enter 0 for the value when rebooting, you cannot cancel the action. Any value greater
than 0 allows you to cancel before the reboot actually takes place.
4.
Select Reboot to perform a software reboot without a power cycle.
44
Working with storage systems
system" on page 45.
Step
5.
"Powering
"Rebooting the storage