Resetting All Settings; Phenomena That May Be Easy To Be Mistaken For Machine Defects - Hitachi CP-WX3014WN Operating Manual

Lcd projector - 720p - hdtv - 16:10
Hide thumbs Also See for CP-WX3014WN:
Table of Contents

Advertisement

Resetting all settings

When it is hard to correct some wrong settings, the FACTORY RESET function of
SERVICE item in OPTION menu (
as LANGUAGE, LAMP TIME, FILTER TIME, FILTER MESSAGE, SECURITY and
NETWORK) to the factory default.
Be sure to set FAN SPEED after resetting all the settings (

Phenomena that may be easy to be mistaken for machine defects

About the phenomenon confused with a machine defect, check and cope with it
according to the following table.
Power does
not come on.
Neither sounds
nor pictures are
outputted.
(continued on next page)
Correctly connect the power cord.
Please disconnect the power plug from the power outlet,
and allow the projector to cool down at least 10 minutes,
then turn the power on again.
Please turn the power off and disconnect the power
plug from the power outlet, and allow the projector to
cool down at least 45 minutes. After the projector has
sufficiently cooled down, please make confirmation of
the attachment state of the lamp and lamp cover, and
then turn the power on again.
Correctly connect the connection cables.
Correctly set up the signal source device by referring to
the manual of the source device.
Select the input signal, and correct the settings.
AV MUTE may be active.
Refer to the item "Sound does not come out" and "No
pictures are displayed" on the next page to turn off the
MUTE and BLANK functions.
62) can reset all settings (except settings such
Troubleshooting
57).
15
15
94
10 ~ 14
20 ~ 22
20, 27,
57,
104,
105
103

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Cp-x3014wnCp-x2514wnCp-x4014wn

Table of Contents