Table 6-9
POST error messages (continued)
Screen message
1803—Processor feature set
is insufficient for current
system settings
1804—A processor feature
and the memory configuration
are incompatible
ERROR: Invalid 1394 GUID
(Invalid electronic serial
number)
ERROR: Invalid electronic
serial number (no number)
ERROR: An unsupported
processor is installed. System
halted
ERROR: A processor requiring
too much power is installed.
System halted
Invalid electronic serial
number
Network Server Mode Active
and No Keyboard Attached
Processor initialization fails
ENWW
Probable cause
Processor feature set is insufficient for
current system settings. The BIOS
settings do not match the support
provided by the processor
A processor feature is incompatible
with the memory configuration.
No electronic serial number is stored
with the system.
No electronic serial number is stored
with the system
Unsupported processor detected.
Unsupported processor detected.
Incorrect serial number registered in
the system.
Keyboard not detected.
Processor defective.
Recommended action
Change the BIOS settings or upgrade the processor.
Restore the previous memory configuration.
To assign a serial number , select Security >System
IDs in the Computer Setup (F10) Utility.
To assign a serial number , select Security >System
IDs in the Computer Setup (F10) Utility.
Replace the processor.
Replace the processor.
To assign a serial number , select Security >System
IDs in the Computer Setup (F10) Utility.
Verify that a functioning keyboard is attached to the
computer.
Replace the processor.
Diagnostic codes and errors 161