Table 9-2
Class: HP_ManagementProcessor
Property name
Description
ElementName
CIM_ManagedSystemElement
OperationalStatus
Property implementation
Description of the Management Processor in the
format: <X> HP Management Processor - <product
name> where <X> indicates the MP Is Active or
Inactive/Disabled and <product name> is the name of
the MP product (same as the product name in property
ElementName)
For example, Active HP Management Processor –
Integrated Lights Out (iLO)
Product name of the management processor.
Examples:
•
Remote Insight Board Lights Out Edition II (RILOE-II)
•
Integrated Lights Out (iLO)
•
Integrated Lights Out 2 (ILO2)
Enumerators indicating the Management Processor
operational status (refer to OperationalStatus mapping
table in HP Management Processor (MP) Lite Profile for
specific descriptions of when each value is populated).
•
OperationalStatus[0] contains MP operational
status:
○
0 (Unknown), when NICCondition=0
○
2 (OK), normal operation
○
3 (Degraded), when NICCondition=5
○
6 (Error), when NICCondition=6 or MP
software interface fails
•
OperationalStatus[1] contains NIC status (when MP
is enabled):
○
0 (Unknown), when NICCondition=0 or MP
software interface fails
○
2 (OK), normal operation
○
3 (Degraded), when NICCondition=5
○
6 (Error), when NICCondition=6
○
10 (Stopped), when NICCondition=3
○
15 (Dormant), when NICCondition=4
8BManagement Processor Lite 92