Table 16-64
HPSCSI_DeviceIndication: Physical Drive status is set to Predictive Failure
Property name
ImpactedDomain
BladeBay *
BladeName *
EnclosureName *
RackName *
RackUID *
SystemVirtualSerialNumber
SystemVirtualUUID
HP_HardwareIndication
HWFirmwareVersion
HWLogicalLocation
HWManufacturer
HWSerialNumber
HP_DeviceIndication
DeviceModel
Table 16-65
HPSCSI_DeviceIndication: Physical Drive status OFFLINE
Property name
CIM_Indication
IndicationIdentifier
PerceivedSeverity
IndicationTime
CIM_AlertIndication
Description
AlertingMangedElement
AlertingElementFormat
AlertType
EventID
ProviderName
Property implementation
3 (Enclosure) for c-Class blade systems
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
HP_BladeCSLocation.LocationInformation[0]
HP_ComputerSystem.Name
HP_BladeEnclosureCS.Name
Rack name if one exists
Rack Unique Identifier if one exists
Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
Disk firmware version string
Disk Location string
Disk Manufacturer string
Disk Serial Number
Disk Model string
Property implementation
GUID string generated at indication
6 (Critical)
Time of indication
The physical drive is offline and can no longer return
data. No further status is available.
WBEM path of the HPSCSI_DiskDrive class instance
2 (CIMObjectPath)
5 (Device Alert)
13
SCSIHBA
15BSCSI HBA 372