Table 13-91
HPSA_StorageVolumeIndication: Logical Drive status changed to OK
Property name
HPSA_StorageVolumeIndication
DeviceOperationalStatus
DeviceOperationalStatusPrevious
Table 13-92
HPSA_StorageVolumeIndication: Logical Drive status changed to ERROR
Property name
CIM_Indication
IndicationIdentifier
PerceivedSeverity
IndicationTime
CIM_AlertIndication
Description
AlertingMangedElement
AlertingElementFormat
AlertType
EventID
ProviderName
RecommendedActions
SystemName
SystemCreationClassName
HP_AlertIndication
Summary
EventCategory
ProbableCause
Property implementation
Current OperationalStatus values for Storage Volume
•
DeviceOperationalStatus[0]:
HPSA_StorageVolume.OperationalStatus[0]
•
DeviceOperationalStatus[1]:
HPSA_StorageVolume.OperationalStatus[1] (This
index is only populated if there is addional Vendor
unique status available)
Previous OperationalStatus values for Storage Volume
•
DeviceOperationalStatusPrevious[0]:
HPSA_StorageVolume.OperationalStatus[0]
•
DeviceOperationalStatusPrevious[1]:
HPSA_StorageVolume.OperationalStatus[1] (This
index is only populated if there is addional Vendor
unique status available)
Property implementation
GUID string generated at indication
5 (Major)
Time of indication
Logical Drive Status has changed to ERROR status.
WBEM path of the HPSA_StorageVolume class
2 (CIMObjectPath)
5 (Device Alert)
1202
SmartArray
Check for physical drive failed or removed.
Name of the computer system generating the indication
CreationClassName of the computer system generating
the indication
Logical Drive Status is now ERROR
6 (Primary Storage)
86 (Disk Failure)
12BSmart Array 207