Table 15-27
Property name
SerialNumber
Tag
Version
CIM_PhysicalPackage
RemovalConditions
CIM_PhysicalFrame
CIM_Chassis
HP_StorageEnclosure
Location
HPSAS_StorageEnclosure

HPSAS_StorageEnclosureProcessor

15-3-27
HPSAS_StorageEnclosureProcessor represents the management processor within a Storage Enclosure.
This instance contains the operational status for all managed components in the enclosure if
applicable.
Table 15-28
Property name
CIM_ManagedElement
ElementName
CIM_ManagedSystemElement
OperationalStatus[0,1, 2, 3 ]
CIM_LogicalElement
Class: HPSAS_StorageEnclosure (HP_StorageEnclosure)
Class: HPSAS_StorageEnclosureProcessor (CIM_ComputerSystem)
Property implementation
Enclosure Serial Number
N/A is reported if there is no serial number (for
example, internal enclosures).
Opaque key
N/A—Not Available in this implementation
2 (Not Applicable)
See HP Storage Enclosure Profile
Property implementation
Port: <m> Box: <n>, where <m> is the port and <n> is
the box number
Operational status for enclosure and associated power
supplies, fans, and sensors.
The use of OperationalStatus is described in the HP
Storage Enclosure Profile. Index values are populated
as follows:
Index[0]—Enclosure status:
0 (Unknown)
2 (OK)
3 (Degraded)
6 (Error)
Index[1]—Fan status (See Profile)
Index[2]—Power Supply status (See Profile)
Index[3]—Temp Sensor Status (See Profile)